To remove the calibration rotor from the shaft, handle it from the fl at side. Do not hold it from the spacer.
C83
Calibration of the unbalance measurement with wheel/test rotor.
Options
:
None
Special function
:
In case of using of a wheel, use a 6.5”x15” steel rim with a maximum unbalance of 10g in each
side.
Description:
With the calibration of the unbalance measurement the following are determined:
-
the sensitivity of the transducers,
-
the phase difference of the transducer signals,
-
the comparative data for readjustment by the operator and temperature compensation
-
the phase shift of the unbalance signal amplifi ers and
-
the angular deviation
After the 1
st
step, that is the measuring run, a beep signal is heard.
After acknowledgement/setting of weight size in step 2 a beep signal is heard (in addition to the beep made by the
key).
In step 6 the ambient transducer temperature will be read out for 1 second.
Mount the calibration tool or the wheel on the balancer shaft: Set the calibration tool or wheel data.
Step 1:
Press the “
START
” button to begin the measuring run.