63
0X001005
PO EEP2 RD
Turn off and back on the machine.
If the problem still persists:
Load the software.
If the problem still persists:
Replace the Optoencoder.
If the problem still persists:
Replace the IBP2 box.
If the problem still persists:
Call Snap On
C Codes
C74, C75, C85, C86, C115, C84, C88, C90
0X001006
PO EEW1 WR
Turn off and back on the machine.
If the problem still persists:
Load the software.
If the problem still persists:
Replace the IBP2 box.
If the problem still persists:
Call Snap On
C codes
C74, C75, C86, C115, C84, C88, C90
0X001007
PO EEW2 WR
Turn off and back on the machine.
If the problem still persists:
Load the software.
If the problem still persists:
Replace the Optoencoder.
If the problem still persists:
Check the IBP box
If the problem still persists:
Call Snap On
C codes
C74, C75, C85, C86, C122, C115, C84, C88, C90
0X001020
DC OVERRUN
Check if the main shaft turns free.
If the problem still persists:
Check if the brake is correctly adjusted.
If the problem still persists:
Check the main shaft Optoencoder
If the problem still persists:
Check the main shaft polygonal ring.
If the problem still persists:
Call Snap On
C codes
C74, C75, C85, C86, C115, C84, C88, C90
SM HOF GEODYNA 7600 Rel.D