67
0X001042
SAPE 2D LOW VOLT
Check the Diameter potentiometer connector and cable.
If the problem still persists:
Check the Diameter potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90
0X001043
SAPE 2D HIGH VOLT
Check the Diameter potentiometer connector and cable.
If the problem still persists:
Check the Diameter potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90
0X001046
1D SAPE INVALID CAL
Check the Distance potentiometer connector and cable.
If the problem still persists:
Check the Distance potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90
0X001047
2D SAPE INVALID CAL
Check the Diameter potentiometer connector and cable.
If the problem still persists:
Check the Diameter potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90
0X001050
SIDE CAL BAR
Perform the calibration C115 with weight in the correct side.
If the problem still persists:
Call Snap On
C Codes
C64, C115, C84, C88, C90
0X001051
SIDE CAL USER
Perform the User calibration with weight in the correct side.
If the problem still persists:
Call Snap On
C Codes
SM HOF GEODYNA 7600 Rel.D