41
Ø
Mount the belt and the drive pulley optoencoder.
Ø
Mount the power clamp device.
Ø
Connect the electromagnetic brake wires to the connector X43 of the IBP box.
Ø
Mount the weight tray.
Ø
Switch on the machine.
Ø
Calibrate with C84, C90.
Ø
Check if the balancer works fi ne.
4.22 CHECK AND REPLACEMENT OF ELECTRIC BRAKE / CLAMPING PEDAL SWITCH
"
:
Medium and big Phillips screwdriver, 3, 5 and 6mm allen key, 10mm wrench, scissors.
6
:
2.5h
i
:
Defective mechanical brake cable may cause the following malfunctions:
1. Machine does not clamp or unclamp.
2. Balancer show E89 turning it on.
TO CHECK THE SWITCH
Ø
Turn on the balancer and check the switches with service code C56.
Ø
Remove the two screws securing the brake pedal assembly.
Ø
Remove the weight tray.
Ø
Remove the cover from the electronic box.
Ø
Rotate either the microswitch activator or the micro switch on the brake pedal assembly until the circuit is open.
Ø
Make sure that the circuit closes when the brake pedal is depressed or pressed
TO ADJUST AND REPLACE THE SWITCH
Ø
Lift the balancer from the fl oor.
Ø
Remove the defective switch from the pedal.
Ø
Remove the weight tray.
Ø
Release the switches wires inside of the cabinet.
Ø
Cut the wires of the defective switch and connect them to those ones of the new switch.
Ø
Remove the wires of the defective switch from the connector X13
Ø
Fit the new switch on the pedal bracket and secure it with a torque wrench at 0.5Nm / 4,4 lbs-in)