User calibration with Power Clamp
Options :
None
Special function:
None
Description:
Re-calibration serves to compensate for sensitivity losses of the transducers.
Attach the spacer ring, two small centring cones and clamping sleeve without the clamping head to the adaptor
sleeve, and initiate the clamping operation.
Set code C14.
The following is displayed: 1. and the symbol of the START key.
Press the ST
ART key to start the fi rst extended measuring run (twice as long as regular measuring run).
(Instantaneous compensation of residual unbalance.)
The following is displayed after the run: 2. and the symbol of the START key.
Tighten the calibration weight to the adaptor fl ange and press the START key to initiate the second
Remove calibration weight and place in storage location.
Press "ESC" key to escape the C code.
Comments:
None
C21
Indication of the program version & model number
Options:
Indication of model designation
Special function:
None
Description:
Indication of program version number.
Press Option key to read out the model designation.
Comments
:
None
C22
Unclamping of power clamp locked
Options:
0 *
:
Unclamping of power clamp device enabled
1
:
Unclamping of power clamp device locked.
Special function:
None
Description:
The power clamp device is locked in clamped position.
Comments:
The asterisk „*“ marks the factory-adjusted default.
C23
Enable/disable of power clamp
Options:
0 *
:
Power clamp device enabled
1
:
Power clamp device disabled.
Special function:
None
Description:
Set the function to 1 to disable the power clamp after the clamping of the fl ange for rim without center
bore.