87
open.
With p-variants and manual indexing of the wheel with open wheel guard, a braking pulse will be initiated shortly
before reaching one of the correction positions.
The selected mode of operation can be transferred to the permanent memory.
Comments:
The asterisk “*“ marks the factory-adjusted default
C12
Recall counter - Only balancers with digital display
Options
(Only press the "Continues" key, do not turn the wheel)
1
:
Total number of measuring runs
2
:
Number of measuring runs where balance quality was considered OK
3
:
Number of optimisations or minimisations
4
:
Number of measuring runs in service mode
5
:
Number of measuring runs since the last calibration
6
:
Total number of clamping operations (p models only)
Special function:
None
Description:
Various counter readings.
Comments:
This mode has been adjusted to usual sequences of operation.
C13
Starting measurement run by closing the wheel guard
Options:
0 : No start of measurement by closing the wheel guard
1* : Start of measurement by closing the wheel guard
Special function:
None
Description:
The chosen mode of operation can be transferred to the permanent memory.
Comments:
The asterisk „*“ marks the factory-adjusted default
C14
User calibration
Options :
None
Special function:
None
Description:
Re-calibration serves to compensate for sensitivity losses of the transducers.
Mount adaptor
without
calibration weight, wheel, clamping nut, centring cone and spacer ring on the main shaft.
Set code C14.
The following is displayed: 1. and the symbol of the START key.
Press the START key to start the fi rst extended measuring run (twice as long as regular measuring run).
(Instantaneous compensation of residual unbalance.)
The following is displayed after the run: 2. and the symbol of the START key.
Tighten the calibration weight to the adaptor fl ange and press the START key to initiate the second
Remove calibration weight and place in storage location.
Press "ESC" key to escape the C code.
Comments:
None