86
precision/FINE key is now pressed to disable the suppression of minor unbalance readings temporarily, this may result
in unbalance readings that are higher than the threshold in other than the normal balancing mode. This is due to the
fact that larger balance weights are usually required for adjacent correction planes and small diameters in the rim disc.
The threshold value can be transferred to the permanent memory.
Comments:
The unit of measurement is chosen according to the one set with C3.
C10
Saving the user settings in the POs (permanent memory)
Options:
0 * : No storage
1 : Data is stored in the permanent memory
Special function:
None
Description:
Set code C10 to save user settings in the permanent memory. To do so, use the option
selection to set 1. Acknowledge by pressing the Acknowledgment key.
All data so far temporary is stored in the permanent memory. This is acknowledged by a three-tone signal.
The following modes of operation will be stored by pressing the Acknowledgment key:
Function:
FUNCTION
STATUS / VALUE
CODE
Resolution of unbalance readings
Low / High
C1
Suppression of minor unbalance readings
Off / On
C2
Measurement units of the unbalance readings
Grams / Ounces
C3
Compensation of adaptor unbalance
Off / On
C4
Automatic braking on lifting the wheel guard
Off / On
C5
Number of revolutions for measurement
10-25
C6
Threshold for unbalance suppression in grams/ounces
3.5 -20 g
0.12 - 0.71 oz
C8
Position brake and indexing
Off / On
C11
Start of measurement by closing wheel guard
Of f/ On
C13
Unclamping of power clamp locked
Off / On
C22
Actuation direction of pedal for clamping/releasing
Off / On
C26
C11
Position brake after measuring run (Power Clamp)
Options
0
:
No position brake after measuring run
1*
:
Position brake after measuring run for left plane
2
:
Position brake after measuring run for right plane
Special function:
None
Description:
T
he position brake stops the main shaft in or near the correction position by initiating a braking pulse.
The position brake will be active after setting the on state and after a measurement run has been carried out with an
unbalance display for the correction plane exceeding the threshold value.
Option = 1:
After the measurement run the wheel is braked for the left-hand correction plane. If the unbalance in the
left-hand correction plane is smaller than the threshold, the wheel will be braked for the right-hand correction plane.
Indexing of the wheel for the right-hand correction plane is initiated by pressing the START key while the wheel guard
is open.
Option = 2:
After the measurement run the wheel is braked for the right-hand correction plane. If the unbalance in the
right-hand correction plane is smaller than the threshold, the wheel will be braked for the left-hand correction plane.
Indexing of the wheel for the left-hand correction plane is initiated by pressing the START key while the wheel guard is
SM HOF GEODYNA 7600 Rel.D