96
Special function:
None.
Description:
Values for both transducers in mm. Reference mark is the zero reference of Geodata
Values for both transducers in mm.
Reference mark is the zero reference of Geodata (right-hand edge of machine cabinet for geodata)
1. Field : Rear transducer: 212 - 226
2. Field : Front transducer: -1500 to -10000
Comments:
The shown values are those calculated in the latest calibration performed, not those saved from the
latest C90.
C67
Display phase stability of the vpm system as measured with C code 83/115
Options:
None.
Special function:
None.
Description:
None
Reading with screen balancers:
1. Field : distance-dependant phase shift of rear transducer
2. Field : phase shift between rear and front transducers.
Comments:
The shown values are those calculated in the latest calibration performed, not those saved from the
latest C90.
C69
Successive measuring runs with pauses
Options.
In step 1:
0 to 50 : First pause, which simulates the weight application (init value = 50 seconds).
In step 2:
0 to 170 : Second pause, which simulates the (un)clamping of the wheel (init value = 170 seconds)
In step 3:
Only models with power clamp
0
:
Do not unclamp/clamp the wheel
1
:
Unclamp/Clamp the wheel after the second pause.
Special function:
please refer to the service function C63
Description:
Mount an unbalanced wheel on the shaft.
Displayed values and usage of this service function is the same as service code 63, with the except of the pauses and
the unclamp/clamp cycle.
Comments:
None
C71
Display angular deviation of VPM system as measured with C code C83 / C115
Options.
: None.
Special function:
None.
Description:
Values for both transducers.
Reading on screen machine must be:
1. Field : Rear transducer 178-182
2. Field : Front transducer 358-002Reading with screen machine:
Comments:
The shown values are those calculated in the latest calibration performed, not those saved from the
latest C90.
SM HOF GEODYNA 7600 Rel.D