84
C1
Resolution of unbalance readings
Options:
0* : Low resolution
1 : High resolution
Special function
:
WHEEL TYPE
RESOLUTION OF UNBALANCE READINGS
SUPPRESSION OF
MINOR READINGS
LOW
HIGH
1, 2, 3, 6 (car)
5 Grams
1 Gram
threshold value x 1
4, 5 (light truck)
10 Grams
2 Grams
threshold value x 2
1, 2, 3, 6 (car)
0.25 Ounces
0.05 Ounces
threshold value x 1
4, 5 (light truck)
0.5 Ounces
0.1 Onunce
threshold value x 2
The selected mode of operation can be transferred to the permanent memory.
Comments:
The asterisk “*“ marks the factory-adjusted default.
C2
Suppression of minor unbalance readings
Options:
0 : Suppression off
1 : Suppression on
Special function:
None
Description: In order to signal to the operator that the required balance quality for a correction plane has
been reached, the unbalance below the threshold set using C8 will be read out as zero. In some cases this
suppression may not be useful and can, therefore, be switched off temporarily using the precision/FINE key,
or permanently using code C2.
The chosen mode of operation can be transferred to the permanent memory.
Comments:
None.
C3
Measurement units of unbalance readings
Options:
0
:
Readings in gram
1
:
Readings in ounce
Special function
:
None
Description:
The state defi nes the measurement unit of the unbalance readings (gram/ounce) active after power-
on and execution of C0.
The chosen mode of operation can be transferred to the permanent memory.
Comments:
None
C4
Compensation of adaptor unbalance
Options:
None
Special function:
None
Description:
Set code C4, close the wheel guard and start an extended measuring run by lowering the wheel
SM HOF GEODYNA 7600 Rel.D