6. Now switch off the balancer, remove the MMC/SD card and install the
protection again. Wait 10 seconds.
Switch on the machine and use C47 to select again the same model to
update POs (permanent
objects memory).
5.3 IN THE FIELD REPROGRAMMING OF BALANCER
After software down loading, perform service codes in the following order:
C47
- Select machine model: after the
selection, the machine will make three audible beeps followed by the automatic turning off and on again.
•
C47
-
Select machine model: after the selection, the machine will make three audible beeps followed by the
automatic turning off and on again.
•
C80
- Calibration of inner SAPE gauge arm
•
C81
- Measurement of fl ange to zero plane distance
•
C82
- Calibration of sonar
•
C83
- Basic calibration of vibratory system
with wheel
•
C84
- Measurement of residual main shaft unbalance
•
C88
- Adjustment of 12h position
•
C115 -
Basic calibration of vibratory system
with calibration rotor
•
C120 -
Enable/Disable laser pointer
•
C122 -
Laser pointer calibration
•
C130 -
Calibration of the touch screen.
•
C90
- Saving calibration data
The machine is now ready for use.
5.4 RECOMMENDED SERVICE STEPS
In case of an error it is recommended to perform some service code to check the system. The following are some
common service codes for this job.
•
C28
- Indicate the content of the error record
•
C54
- Some more testing for the incremental encoder of the main shaft
•
C55
- Check lines Voltage
•
C56
- Check the pedal switches. The switches and the Function-Code to lock the power clamp should be
checked if the power clamp does not work
•
C63
- Continuous measurements for test of valid results.
•
C67
- Indicate the phase stability/shift of the vibratory system
•
C71
-
Display angular deviation of the vibratory system as measured with C code 115.
•
C72
- Measure the angular deviation of the vibratory system
•
C74
- Check the incremental encoder of the main shaft
•
C75
- Check Voltages of SAPE potentiometers (AD8, AD9, AD10) or perform STEP 1 of C80.
•
C80
- Check Voltages for left SAPE
ATTENTION!
This is a calibration function; interrupt this function after the test in STEP 1 with the STOP or ESC
key.
•
C81
- Check Voltages for right SAPE
ATTENTION!
This is a calibration function; interrupt this function after the test in STEP 1 with the RETURN key
•
C82
- Check Sonar sensor
SM HOF GEODYNA 7600 Rel.D