background image

Fasep 2000 srl

Rev. 1.0

Videotronic V644.G3: User

’s Manual

27 november 2013

For any information, please contact:

www.fasep.it

e-mail:

[email protected]

FASEP 2000 srl
Via Faentina 96
50032 Ronta (Fi) Italy
Tel. #39 055 840 3126
Fax #39 055 840 3354

i

VIDEOTRONIC V644.G3
USER

’S MANUAL

Содержание VIDEOTRONIC V644.G3

Страница 1: ...V644 G3 User s Manual 27 november 2013 For any information please contact www fasep it e mail info fasep it FASEP 2000 srl Via Faentina 96 50032 Ronta Fi Italy Tel 39 055 840 3126 Fax 39 055 840 3354...

Страница 2: ...ence breakdown accidents due to unauthorized modifications of the unit use of non original or unauthorized accessories see Accessories listing in this manual for a list of original accessories availab...

Страница 3: ...alancer and position weight 2 6 5 Calibration ALU SE 3 5 6 Calibration SME 3 6 7 MEASUREMENT AND CORRECTION OF UMBALANCE 3 7 7 1 Placing the wheel rim on the wheel balancer 3 7 7 2 Input of Rim Dimens...

Страница 4: ...tely This unit is designed for indoor use only see Environmental Data appendix for reference CAUTION This unit is designed to spin vehicle wheels only within the range of dimensions and weight approve...

Страница 5: ...arly provided with a ground terminal 2 4 5 Make sure that Power Rate Specifications for your wheel balancer refer to nameplate on the wheel balancer comply with those provided by the external power so...

Страница 6: ...ember 2013 2 2 3 USE OF CONTROL PANEL 3 1 Meaning of the icons on the screen Select balancing mode APS Function Calibration Delete last character in input activation code Change selection Set default...

Страница 7: ...previous page Fine resolution Access to Information center Access to page measures Laser calibration Put in the rod laser in rest position Start laser Extract fully rod laser Manul input measures Set...

Страница 8: ...tware Reset partial statistics Reset variation in page Sensor Save Set measures Go to setup men Skip current operation Split function Stop turning wheel Key up View men and selection UP DOWN Automatic...

Страница 9: ...onstant low or high weight readings c indicated point of unbalance constantly wrong d more than 2 spins required to balance wheels repeatedly Switch on the wheel balancer Select SET UP CALIBRATION SET...

Страница 10: ...SET OK CHECK CALIBRATION SET OK Put a wheel on the shaft and press START Fig 46 Put the calibration weight Fig 47 and press SET OK Close the wheel guard or press START At the end of the spin 160 0 wil...

Страница 11: ...l balancer MAIN MENU MENU RESET CALIB ALU SE CALIBRATION SET OK fig 49 Put the rod on rest position fig 49 and press SET OK Put the rod on the flange fig 50 and press SET OK Select width of wheel Put...

Страница 12: ...ovember 2013 3 6 6 Calibration SME Switch on the wheel balancer MAIN MENU MENU RESET CALIB SME CALIBRATION SET OK fig 52 Put the rod on rest position fig 52 and press SET OK Put the rod fig 53 and pre...

Страница 13: ...nges is of basic importance for correct balancing Good results depend on proper performance of these procedures To accurately clean up the superficial ones of connection before whichever operation CAU...

Страница 14: ...istance IN2 Press ALU MODE untill the required position of weight is on the video fig 58 Insert the distance IN1 Insert the distance IN2 7 4 Detecting and correcting umbalance 7 4 1 After setting whee...

Страница 15: ...weight using LASER Turn the wheel until the position weight indicators of one side are both green fig 64 The laser come out to show the point of application of the weight fig 65 Apply the weight on th...

Страница 16: ...e rim and put the wheel on the shaft fig 67 Spin the wheel Select the optimization and follow the video instruction IWARNING Balancing with flanges put the accessories assembled to the rim during the...

Страница 17: ...s Manual 27 november 2013 5 1 9 SPECIAL FUNCTIONS 9 1 Language selection 9 1 1 MAIN MENU SET UP USER SET UP LANGUAGE SET OK 9 1 2 Select the language and press SET OK 9 2 Setup 9 2 1 MAIN MENU SET UP...

Страница 18: ...nt 400W Speed Balancing 98RPM Measuring time 4 15 s Accuracy 1grammo 1 28 once Wheel Dimensions Diameter Rim diameter 8 200 mm 26 650 mm Rim Width with wheel guard max 16 415mm Wheel Weight max 90 Kg...

Страница 19: ...ndirectly by unauthorized service Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit G NOTE As this unit runs at speed below 100rpm a safety...

Страница 20: ...cover is open ERR 7 Measuring cycle was interrupted ERR 8 Calibration weight was not inserted ERR 9 Activation code not correct ERR 10 Overflow in calculations ERR 11 Serial number is wrong ERR 12 Ser...

Страница 21: ...consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery The recycling of the materials will help to conserve natural resources...

Страница 22: ...FASEP 2000 srl Data 27 11 13 Pag 1 di 2 E611 xxx Istruzioni d Installazione Equilibratrice V644 G3 xxx Preparation for use Rev R0 A DETTAGLIO A 2 1 3 Svasatura di riferimento countersinking reference...

Страница 23: ...Preparation for use Rev R0 B DETTAGLIO B C DETTAGLIO C 4 5 6 Accertarsi che la punta del grano si accoppi con la svasatura sul tubo e bloccare Make sure the tip of the sceew mate with the flare on th...

Страница 24: ...Attenzione Nella movimentazione della macchina attenzione a non danneggiare la pedaliera Warning In the handling of the machine care not to damage the pedals...

Отзывы: