1–7
Tables for 400V
class inverters
Note that
“General Specifications” on page 1–9
covers all SJ300 inverters, followed by
footnotes for all specifications tables. The 400V models in the upper table below (1 to 15 hp)
include internal dynamic braking units (see
Item
400V Class Specifications
SJ300 inverters,
400V models
U.S. version
007HFU
015HFU
022HFU
040HFU
055HFU
075HFU
110HFU
European ver.
007HFE
015HFE
022HFE
040HFE
055HFE
075HFE
110HFE
Applicable motor size *2
HP
1
2
3
5
7.5
10
15
kW
0.75
1.5
2.2
4.0
5.5
7.5
11
Rated capacity (400 / 480V) kVA
1.7 / 2.0
2.6 / 3.1
3.6 / 4.4
5.9 / 7.1
8.3 / 9.9
11 / 13.3
15.9/19.1
Rated input voltage
3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%
Rated input current (A)
2.8
4.2
5.8
9.5
13
18
25
Rated output voltage *3
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
Rated output current (A)
2.5
3.8
5.3
8.6
12
16
23
Efficiency at 100% rated output, %
89.5
92.3
93.2
94.0
94.4
94.6
94.8
Watt loss,
approximate (W)
at 70% output
76
102
127
179
242
312
435
at 100% output
88
125
160
235
325
425
600
Starting torque *6
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
Dynamic braking
approx. % torque,
short time stop *7
internal res. only
50%
20%
10%
with external res.
200%
140%
100%
70%
DC braking
Variable operating frequency, time, and braking force
Weight
kg / lb
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
5 / 11
5 / 11
Item
400V Class Specifications
SJ300 inverters,
400V models
U.S. version
150HFU
185HFU
220HFU
300HFU
370HFU
450HFU
550HFU
European ver.
150HFE
185HFE
220HFE
300HFE
370HFE
450HFE
550HFE
Applicable motor size *2
HP
20
25
30
40
50
60
75
kW
15
18.5
22
30
37
45
55
Rated capacity (400 / 480V) kVA
22.1 / 26.6
26.3 / 31.5
33.2 / 39.9
40.1 / 48.2
51.9 / 62.3
62.3 / 74.8
76.2/91.4
Rated input voltage
3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%
Rated input current (A)
35
42
53
64
83
99
121
Rated output voltage *3
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
Rated output current (A)
32
38
48
58
75
90
110
Efficiency at 100% rated output, %
94.9
95.0
95.0
95.1
95.1
95.1
95.1
Watt loss,
approximate (W)
at 70% output
575
698
820
1100
1345
1625
1975
at 100% output
800
975
1150
1550
1900
2300
2800
Starting torque *6
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
Dynamic braking
approx. % torque,
short time stop *7
w/o braking unit
10%
with braking unit
40–200%
40–200%
35–200%
110–170%
90–150%
70–120%
60–100%
DC braking
Variable operating frequency, time, and braking force
Weight
kg / lb
12 / 26.4
12 / 26.4
12 / 26.4
20 / 44
30 / 66
30 / 66
50 / 110
Содержание SJ300 Series
Страница 2: ......
Страница 138: ......
Страница 212: ......
Страница 213: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 243: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 268: ......
Страница 269: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 285: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 294: ......