Troubleshooting
T
roub
leshooting
and Maintenance
6–4
The motor speed will not reach the
target frequency (desired speed).
•
If using the analog input, is there
current or voltage at [O] or [OI]?
•
Check the wiring.
•
Check the potentiometer or
signal generating device.
•
Is the load too heavy?
•
Reduce the load.
•
Heavy loads activate the
overload restriction feature
(reduces output as needed).
•
Is the inverter internally limiting the
output frequency?
•
Check max frequency setting
(A004)
•
Check frequency upper limit
setting (A061)
•
If using analog inputs, check
their settings (A101– A104)
or (A111–A114), or (A011–
A014)
The rotation is unstable.
•
Is the load fluctuation too great?
•
Is the supply voltage unstable?
•
Is the problem occurring at a particular
frequency?
•
Increase the motor capacity
(both inverter and motor).
•
Fix power supply problem.
•
Change the output frequency
slightly, or use the jump
frequency setting to skip the
problem frequency.
The RPM of the motor does not
match the inverter output
frequency setting.
•
Is the maximum frequency setting
A004 correct?
•
Does the monitor function D001
display the expected output frequency?
•
Verify the V/F settings match
motor specifications.
•
Make sure all scaling (such as
A011 to A014) is properly set.
A parameter
will not
change after
an edit
(reverts to old
setting).
True for certain
parameters
•
Is the inverter in Run Mode? Some
parameters cannot be edited during
Run Mode.
•
Put inverter in Stop Mode
(press the Stop/reset key). Then
edit the parameter.
True for all
parameters
•
If you’re using the [SFT] intelligent
input (software lock function)—is the
[SFT] input ON?
•
Change the state of the SFT
input, and check the B031
parameter (SFT mode).
Symptom/condition
Probable Cause
Solution
Содержание SJ300 Series
Страница 2: ......
Страница 138: ......
Страница 212: ......
Страница 213: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 243: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 268: ......
Страница 269: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 285: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 294: ......