“H” Group: Motor Constants Functions
Configur
ing Dr
iv
e
P
a
ra
meters
3–64
H224 Motor constant J,
2nd motor
Ratio (unit-less), range is
1.0 to 1000
✘ ✘
According to
inverter rating
—
>H224 2AUX
J 000.055
H030 Auto-tuned motor
constant R1, 1st motor
Auto-tuning data
✘ ✘
According to
inverter rating
Ohm
>H030 AUX
A-R1 00.489ohm
H230 Auto-tuned motor
constant R1, 2nd motor
Auto-tuning data
✘ ✘
According to
inverter rating
Ohm
>H230 2AUX
A-R1 00.489ohm
H031 Auto-tuned motor
constant R2, 1st motor
Auto-tuning data
✘ ✘
According to
inverter rating
Ohm
>H031 AUX
A-R2 00.355ohm
H231 Auto-tuned motor
constant R2, 2nd motor
Auto-tuning data
✘ ✘
According to
inverter rating
Ohm
>H231 2AUX
A-R2 00.355ohm
H032 Auto-tuned motor
constant L, 1st motor
Auto-tuning data
✘ ✘
According to
inverter rating
mH
>H032 AUX
A-L 005.12mH
H232 Auto-tuned motor
constant L, 2nd motor
Auto-tuning data
✘ ✘
According to
inverter rating
mH
>H232 2AUX
A-L 005.12mH
H033 Auto-tuned motor
constant I
0
, 1st motor
Auto-tuning data
✘ ✘
According to
inverter rating
A
>H033 AUX
A-I0 008.02A
H233 Auto-tuned motor
constant I
0
, 2nd motor
Auto-tuning data
✘ ✘
According to
inverter rating
A
>H233 2AUX
A-I0 008.02A
H034 Auto-tuned motor
constant J, 1st motor
Auto-tuning data
✘ ✘
According to
inverter rating
—
>H034 AUX
A-J 0000.055
H234 Auto constant J,
2nd motor
Auto-tuning data
✘ ✘
According to
inverter rating
—
>H234 2AUX
A-J 0000.055
H050 PI proportional gain for
1st motor
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
✔ ✔
100
100
100
%
>H050 AUX
KSP 0100.0%
H250 PI proportional gain for
2nd motor
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
✔ ✔
100
100
100
%
>H250 2AUX
KSP 0100.0%
H051 PI integral gain for 1st
motor
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
✔ ✔
100
100
100
%
>H051 AUX
KSI 0100.0%
H251 PI integral gain for 2nd
motor
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
✔ ✔
100
100
100
%
>H251 2AUX
KSI 0100.0%
H052 P proportional gain
setting for 1st motor
Range is 0.00 to 10.00
✔ ✔
1.00
1.00
1.00
—
>H052 AUX
KSPP 001.00
H252 P proportional gain
setting for 2nd motor
Range is 0.00 to 10.00
✔ ✔
1.00
1.00
1.00
—
>H252 2AUX
KSPP 001.00
H060 0Hz SLV limit for 1st
motor
Range is 0.0 to 100.0%
✔ ✔
100.
100.
100.
%
>H060 AUX
0SLV-LMT 100.0%
H260 0Hz SLV limit for 2nd
motor
Range is 0 to 100.0%
✔ ✔
100.
100.
100.
%
>H260 2AUX
0SLV-LMT 100.0%
H070 Terminal selection PI
proportional gain setting
Range is 0 to 99.9 / 100.0 to
999.9 / 1000%
✔ ✔
100.0
100.0
100.0
%
>H070 AUX
CH-KSP 0100.0%
H071 Terminal selection PI
integral gain setting
Range is 0 to 99.9 / 100.0 to
999.9 / 1000%
✔ ✔
100.0
100.0
100.0
%
>H071 AUX
CH-KSI 0100.0%
H072 Terminal selection P
proportional gain setting
Range is 0.00 to 10.00
✔ ✔
1.00
1.00
1.00
—
>H072 AUX
CH-KSPP 001.00
“H” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(EU)
–FU
(US)
–FR
(JP)
Содержание SJ300 Series
Страница 2: ......
Страница 138: ......
Страница 212: ......
Страница 213: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 243: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 268: ......
Страница 269: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 285: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 294: ......