“B” Group: Fine-Tuning Functions
Configur
ing Dr
iv
e
P
a
ra
meters
3–46
External Brake
Control
The brake control function in the inverter controls external braking used in systems such as
elevators. The purpose of this function is to ensure the inverter is powering the motor before
releasing external brakes that would permit the load to move or coast. This function requires the
configuration and wiring of intelligent input and output terminals. See
for more information.
“B” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(EU)
–FU
(US)
–FR
(JP)
B120
Brake Control Enable
Two option codes:
00 Disable
01 Enable
✘ ✔
00
00
00
—
>b120 BRAKE
Mode OFF
B121
Brake Wait Time for
Release
Sets time delay between
arrival at release frequency
and the brake release signal.
Range is 0.00 to 5.00 sec.
✘ ✔
0.00
0.00
0.00
sec.
>b121 BRAKE
STA-WAIT 0.00s
B122
Brake Wait Time for
Acceleration
Sets time delay after brake
confirmation signal is
received until the inverter
begins acceleration
Range is 0.00 to 5.00 sec.
✘ ✔
0.00
0.00
0.00
sec.
>b122 BRAKE
ACC-WAIT 0.00s
B123
Brake Wait Time for
Stopping
Sets time delay after brake
confirmation signal turns
OFF until decelerating the
inverter to 0 Hz.
Range is 0.00 to 5.00 sec.
✘ ✔
0.00
0.00
0.00
sec.
>b123 BRAKE
STP-WAIT 0.00s
B124
Brake Wait Time for
Confirmation
Sets the wait time for confir-
mation after turn ON/OFF of
brake release. If confirma-
tion is not received during
the specified wait time, the
inverter will trip with an
external brake error.
Range is 0.00 to 5.00 sec.
✘ ✔
0.00
0.00
0.00
sec.
>b124 BRAKE
BRK-WAIT 0.00s
B125
Brake Release
Frequency Setting
Sets the frequency at which
the inverter will output the
brake release signal after
delay set by B121.
Range is 0.00 to 99.99 /
100.0 to 400.0Hz
✘ ✔
0.00
0.00
0.00
Hz
>b125 BRAKE
OPEN-F 000.00Hz
B126
Brake Release Current
Setting
Sets the minimum inverter
current level above which
the brake release signal will
be permitted.
Range is 0% to 200% of
rated current
✘ ✔
Rated current for
each inverter model
A
>b126 BRAKE
OPEN-A 00.16.5A
[BRK] Brake release
[BOK] Brake confirmation
Inverter
External Brake
System
Emergency Brake
(or alarm, etc.)
[BER] Brake error
Содержание SJ300 Series
Страница 2: ......
Страница 138: ......
Страница 212: ......
Страница 213: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 243: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 268: ......
Страница 269: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 285: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 294: ......