Function Key
– This key is used to navigate
through the lists of parameters and functions
for setting and monitoring parameter values.
•
Up/Down (
,
)
Keys
– Use these
keys alternately to move up or down the lists
of parameter and functions shown in the
display, and increment/decrement values.
•
Store (
)
Key
– When the unit is in
Program Mode and the operator has edited a
parameter value, press the Store key to write
the new value to the EEPROM. This param-
eter is then displayed at powerup by default.
If you want to change the powerup default,
navigate to a new parameter value and press
the Store key.
Keys, Modes, and
Parameters
Purpose of the keypad is to provide a way to change modes and parameters. The term
function
applies to both monitoring modes and parameters. These are all accessible through
function
codes
that are primarily 3 or 4-character codes. The various functions are separated into related
groups identifiable by the left-most character, as the table shows.
For example, function “A004” is the
base frequency setting
for the motor, typically 50 Hz or
60 Hz. To edit the parameter, the inverter must be in Program Mode (PGM LED will be ON).
You use the front panel keys to first select the function code “A004.” After displaying the value
for “A004,” use the Up/Down (
or
) keys to edit the value.
NOTE:
The inverter 7-segment display shows lower case “b” and “d”, meaning the same as the
upper case letters “B” and “D” used in this manual (for uniformity “A to F”).
The inverter automatically switches into Monitor
Mode when you access “D” Group functions. It
switches into Program Mode when you access
any other group, because they all have editable
parameters. Error codes use the “E” Group, and
appear automatically when a fault event occurs.
Refer to
“Monitoring Trip Events, History, &
1
2
5 0.0
RUN
STOP
RESET
FUNC.
STR
RUN
PRG
POWER
ALARM
HZ
A
V
kW
%
MIN
MAX
HITACHI
Function
key
Up/Down
keys
Store
key
1
2
STR
Function
Group
Type (Category) of Function
Mode to Access
PGM LED
Indicator
“D”
Monitoring functions
Monitor
or
“F”
Main profile parameters
Program
“A”
Standard functions
Program
“B”
Fine tuning functions
Program
“C”
Intelligent terminal functions
Program
“H”
Motor constant functions
Program
“P”
Expansion card functions
Program
“U”
User-selectable menu functions
Monitor
“E”
Error codes
—
—
1
2
“D” Group
“A” Group
“B” Group
“C” Group
“H” Group
“P” Group
“U” Group
“F” Group
MONITOR
PROGRAM
Содержание SJ300 Series
Страница 2: ......
Страница 138: ......
Страница 212: ......
Страница 213: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 243: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 268: ......
Страница 269: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 285: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 4 D ...
Страница 294: ......