11 Servicing
SMGB0070 rev. 1 - 08/2011
264
Removing other electrical components
Remove the pipe cover following
Removing pipe cover
, see
on page 395
.
Remove three (3) fixing screws and remove the upper co
-
ver.
Remove the electrical box cover.
Removing Electrical Components.
Remove the fixing screw and remove the reactor.
To mount components be sure to match the wiring connec-
tion with the mark band codes.
No.
Part
1
Electrical box cover
2
Partition plate
3
Fuse
4
Electrical box
5
Reactor
6
See the note
1
2
3
4
5
6
1
2
3
4
5
6
N O T E
•
The PCB cannot be removed from the electrical box. To replace PCB the entire electrical box must be replaced.
•
DO NOT touch electrical components while the LED1 (Red) is ON to avoid electrical shock. Wait until the LED
turns off.
Содержание RWM-(H)FSN3E
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 20: ......
Страница 64: ......
Страница 117: ...4 Electrical wiring SMGB0070 rev 1 08 2011 107 4 RWM 8 0 10 FSN3E ...
Страница 118: ...4 Electrical wiring SMGB0070 rev 1 08 2011 108 4 5 2 Electrical wiring diagram for outdoor unit RAS 2HVRN2 ...
Страница 120: ...4 Electrical wiring SMGB0070 rev 1 08 2011 110 RAS 4 6 HVRNME AF ...
Страница 121: ...4 Electrical wiring SMGB0070 rev 1 08 2011 111 4 RAS 4 6 HRNME AF ...
Страница 188: ......
Страница 210: ......
Страница 224: ......
Страница 230: ......
Страница 251: ...10 Spare parts SMGB0070 rev 1 08 2011 241 10 Electrical parts Spare Parts Document EPN 201005 ...
Страница 254: ...10 Spare parts SMGB0070 rev 1 08 2011 244 Electrical parts Spare Parts Document EPN 201005 ...
Страница 257: ...10 Spare parts SMGB0070 rev 1 08 2011 247 10 Electrical parts Spare Parts Document EPN 201005 ...
Страница 336: ......
Страница 423: ......