10 Servicing
377
SMGB0087 rev.0 - 12/2013
10
Vibration-Proof
Rubber 2
Vibration-Proof
Rubber 1
Nut
1
2
3
4
Vibration-proof
Rubber 2
Vibration-proof
Rubber 1
Nut
Fixation of the compressor to the bottom plate
Compressor position
1
2
3
4
Vibration-proof rubber 1
x
x
x
x
Vibration-proof rubber 2
x
x
—
—
Nut
x
x
—
—
8
When brazing the replaced compressor quickly perform the brazing whi-
le the compressor side piping is cooled with wet cloth in order to avoid
the brazing material from entering the compressor.
N O T E
PAY CLOSE ATTENTION not to let the filler metal enter into the compressor
which may result in compressor damage.
Cool the pipe
by wet cloth.
Cool the pipe by
wet cloth
9
Perform in the reverse procedure of removing after replacing the compressor.
a.
Check if the Faston terminal has any abnormality. (Ensure the pull out force greater than 20 Nm). If the Faston
terminal is identified faulty replace with a new one.
b.
Ensure the fixture of the lead wires.
c.
Surely fix the terminal box by tightening the closing nut (Tightening Torque: 3.0 Nm).
d.
Attach the top of sound-proof cover to cover surely the compressor.
e.
Wrap the sound-proof cover to cover the terminal box and the discharge pipe.
f.
Attach the crankcase heater without torsion and gap to the compressor as following figure.
Sound-Proof Cover
Closing Nut
(Tightening Torque: 3 ~ 4N-m)
Thermal Box
Thermal Box
Discharge Pipe
Compressor
2
3
1
Sound-Proof Cover
Surely cover it.
Boss Hole
Foot
Bolt
Fixing Plate
Attachment of Terminal Box
Surely cover it
Closing Nut
(Tightening torque: 3~4 Nm)
Sound-proof Cover
Therminal box
Discharge pipe
Sound-proof Cover
Attachment of Terminal box
Therminal box
Fixing plate
Boss hole
Bolt
Foot
Compressor
Detail of Spring for Crankcase Heater
Crankcase Heater
Compressor
When attaching the spring,
pay attentio not to damage the
crankcase heater.
Содержание RAS-(2-6)HVNP1(E)
Страница 2: ......
Страница 4: ... II ...
Страница 28: ......
Страница 134: ...4 Electrical wiring 120 SMGB0087 rev 0 12 2013 4 7 3 RAS 3HVNP1E 1 230V 50Hz XEK01261_0 ...
Страница 136: ...4 Electrical wiring 122 SMGB0087 rev 0 12 2013 4 7 4 RAS 4 6 HVNP1E 1 230V 50Hz XEK01262_1 ...
Страница 138: ...4 Electrical wiring 124 SMGB0087 rev 0 12 2013 4 7 6 RAS 4 6 HNP1E 3N 400V 50Hz XEK01263_2 ...
Страница 140: ...4 Electrical wiring 126 SMGB0087 rev 0 12 2013 4 7 7 RAS 4 6 HVNC1E 1 230V 50Hz XEK01264_4 ...
Страница 142: ...4 Electrical wiring 128 SMGB0087 rev 0 12 2013 4 7 8 RAS 4 6 HNC1E 3N 400V 50Hz XEK01265_4 ...
Страница 144: ...4 Electrical wiring 130 SMGB0087 rev 0 12 2013 4 7 10 RAS 8 10 HN P C E 3N 400V 50Hz XEK01288_3 ...
Страница 146: ...4 Electrical wiring 132 SMGB0087 rev 0 12 2013 4 7 12 RAS 12HN P C 3N 400V 50Hz 7T146440 ...
Страница 148: ......
Страница 204: ......
Страница 220: ......
Страница 332: ......
Страница 353: ...9 Spare parts 339 SMGB0087 rev 0 12 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211D ...
Страница 354: ...9 Spare parts 340 SMGB0087 rev 0 12 2013 9 6 2 Electrical parts View from P Spare Parts Document EPN 201211D ...
Страница 362: ......
Страница 484: ......
Страница 496: ......
Страница 497: ......