3.5 Waveform Display Settings (as needed)
70
Displayed waveforms can be expanded or compressed along
the horizontal axis. Shorter setting values correspond to greater
magnification.
Make these settings on the
[Setting]
screen.
See:
"Time Setting by Key Operations" (p .52)
Settings can be changed during and after measurement on the
[Wave+Value]
display of the Waveform/Numerical screen(p. 91).
The
[Time/DIV]
range depends on the
[Interval]
setting.
Horizontal axis display options are affected when the recording interval is changed after measuring, be-
cause the options for expanding (or compressing) the displayed axis depend on the recording interval used
when measuring. When using the Logger Utility program with a LAN connection, recording intervals from 100
ms to 2 s are not available, regardless of auto save settings (5 s is automatically selected).
Setting the Display Time Base (horizontal axis magnification)
1 div
Select the time per division.
Setting options:(
∗
: default setting)
100ms
∗
, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min,
2min, 5min, 10min, 20min, 30min, 1h, 2h, 5h, 10h, 12h,
1day [/DIV]
z
: Selectable
, ×
: Not selectable,
U
: Not selectable while measuring
Horizon-
tal axis
Recording interval
[ms]
[s]
[min]
[h]
10
20
50 100 200 500
1
2
5
10
20
30
1
2
5
10
20
30
1
100ms
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
200ms
z
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
500ms
z
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
1s
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
×
2s
z
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
5s
z
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
×
×
×
10s
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
×
20s
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
30s
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
×
×
×
1min
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
×
2min
z
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
5min
z
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
×
×
×
10min
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
×
20min
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
30min
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
×
×
×
1h
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
×
2h
U
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
5h
U
U
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
10h
U
U
U
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
12h
U
U
U
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
1day
U
U
U
U
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
When auto save is enabled for waveforms
100, 200 and 500 ms settings are automatically changed to 1 s when measurement starts, and
the shorter values cannot be selected while measuring.
Содержание LR8400-20
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 26: ...Operating Precautions 14...
Страница 96: ...3 9 Viewing and Editing with the All Channel Settings List 84...
Страница 112: ...4 3 Marking Waveforms and Searching Marks Search Function 100...
Страница 156: ...6 5 Transferring Data to a PC USB Drive Mode 144...
Страница 238: ...10 8 About Communications Commands 226...
Страница 256: ...11 3 LR8501 Universal Unit Specifications 244...
Страница 262: ...12 3 Disposing of the HiLogger 250...
Страница 296: ...Index Index 4...
Страница 297: ......
Страница 298: ......
Страница 299: ......
Страница 300: ......