6.1 About Saving and Loading Data
124
∗
1: Save waveform data in
binary format
if you intend to view it later in the HiLogger or on a PC with
the supplied Logger Utility program. Waveform data and some measurement-related settings
data are saved.
To save a waveform partially, specify a period by using A/B cursors before saving (p. 92).
When the scaling function is set to enable, scaling information as well as raw data (non-converted
data) in binary format are saved. When the data saved in the storage devices is loaded, the con-
verted data will be displayed. The raw data can also be observed by resetting the scaling function
to OFF.
∗
2: When opening a CSV file in a spreadsheet program, note that the number of rows that can be
loaded at one time is limited (p. A8).
∗
3: BMP Format: This is a standard Windows
®
graphics format. These files can be handled by many
graphics programs.
∗
4: Date (YY-MM-DD) folders are automatically created inside the DATA folder.
∗
5: When saved manually. See "Appendix 3 File Naming" (p. A8) for file naming details.
*6: The TXT file extension is applied except when
[Separator:Comma]
is selected on the
[System]
screen.
∗
7: When creating calculation-specific files, an underbar and a serial number (_n) is appended to the
file name, e.g., MEAS0001_1.CSV, MEAS0001_2.CSV, etc.
O: Available/
×
: Not Available
File Type
File
Format
Folder Name
File Name*5
(Auto-numbered
from 1)
Save
Load
Auto
Man-
ual
HiLog
ger
PC
Setting Data
Binary
CONFIG
CONF0001.SET
×
O
O
×
Waveform Da-
ta
∗
1
Binary
DATA\(date)
∗
4
(e.g.: 08-07-30)
WAVE0001.MEM
O
O
O
O
Text
∗
2
DATA\(date)
∗
4
(e.g.: 08-07-30)
WAVE0001.CSV
∗
6
O
O
×
O
Numerical
Calculation
Results
Text
∗
2
MEASUREMENT
MEAS0001.CSV
∗
7
O
O
×
O
Captured
Screen Image
BMP
∗
3
PICTURE
SCR00001.BMP
×
O
O
O
Depending on file size and CF card capacity, each folder can store over
1,000 files. However, the file screen display is limited to a maximum of
1,000 files. Also, as more files are created, more time is needed to start
and stop recording. We recommend setting measurement criteria so that
the number of saved files stays below 1,000 whenever possible.
Содержание LR8400-20
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 26: ...Operating Precautions 14...
Страница 96: ...3 9 Viewing and Editing with the All Channel Settings List 84...
Страница 112: ...4 3 Marking Waveforms and Searching Marks Search Function 100...
Страница 156: ...6 5 Transferring Data to a PC USB Drive Mode 144...
Страница 238: ...10 8 About Communications Commands 226...
Страница 256: ...11 3 LR8501 Universal Unit Specifications 244...
Страница 262: ...12 3 Disposing of the HiLogger 250...
Страница 296: ...Index Index 4...
Страница 297: ......
Страница 298: ......
Страница 299: ......
Страница 300: ......