HYBRID/TROUBLE SHOOTING
3–430
CHECKLIST: P0562 (TC96)
P0562 (TC96)
Abnormality in power supply voltage
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No
1
Inspecting the
voltage of 12 V
battery
1. Set the starter key to the
"LOCK" position.
2. Disconnect the connector of
PCU harness (24P).
3. Set the starter key to the "ON"
position.
4. Using the electrical tester, mea-
sure the voltage between the
terminals of PCU harness
(24P) vehicle connector.
<Measurement conditions>
Starter key: ON
<Tester connections>
PCU harness (24P) vehicle con-
nector
2nd terminal – 16th terminal
<Standard values>
10 – 16 V
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 2.
Inspect the 12
V battery and
charge or
replace if nec-
essary.
When the bat-
tery is normal,
inspect the
vehicle wire
harness (12 V
power supply
circuit).
2
Inspecting the
PCU wire har-
ness (lower
side) for conti-
nuity 1
1. Set the starter key to the
"LOCK" position.
2. Disconnect the inverter con-
nector.
3. Using the electrical tester, mea-
sure the resistance between
the terminals of PCU harness
(24P) lower-side connector and
inverter connector.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (24P) lower-side
connector – inverter connector
2nd terminal – 30th terminal
2nd terminal – 31st terminal
<Standard values>
1
or less (With continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 3.
Replace the
PCU wire har-
ness (lower
side).
3
Inspecting the
PCU wire har-
ness (lower
side) for short
circuit 1
1. Using the electrical tester, mea-
sure the resistance between
the terminals of PCU harness
(24P) lower-side connector and
the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (24P) lower-side
connector
2nd terminal – GND
3rd terminal – GND
<Standard values>
10 k
or more (No continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 4.
Replace the
PCU wire har-
ness (lower
side).