HYBRID/TROUBLE SHOOTING
3–638
1.
Remove the SMR#1 from the high-voltage J/B (in the battery
pack).
2.
Using the electrical tester, measure the resistance between the
SMR#1 terminals.
NO
YES
1.
Remove the SMR#2 from the high-voltage J/B (in the battery
pack).
2.
Using the electrical tester, measure the resistance between the
SMR#2 terminals.
NO
YES
7
Inspecting the SMR#1
SHTS03ZZZ0300412
Measurement
conditions
Tester
connections
Standard values
—
SMR#1 terminal
(switch side)
3rd terminal
–
5th terminal
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 8.
Replace the SMR#1.
After replacement, go to step 8.
8
Inspecting the SMR#2
SHTS03ZZZ0300413
Measurement
conditions
Tester
connections
Standard values
—
SMR#2 terminal
(switch side)
3rd terminal
–
5th terminal
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 9.
Replace the SMR#2.
After replacement, go to step 9.