HYBRID/TROUBLE SHOOTING
3–612
4
Inspecting the
PCU wire har-
ness (lower
side) for short
circuit
1. Disconnect the inverter con-
nector.
2. Using the electrical tester, mea-
sure the resistance between
the terminals of PCU harness
(12P) lower-side connector and
the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (12P) lower-side
connector
1st terminal – 2nd, 5th, 6th, 9th,
10th, 11th terminal
2nd terminal – 1st, 5th, 6th, 8th,
10th, 11th terminal
5th terminal – 1st, 2nd, 6th, 9th,
10th, 11th terminal
6th terminal – 1st, 2nd, 5th, 9th,
10th, 11th terminal
10th terminal – 1st, 2nd, 5th, 6th,
9th, 11th terminal
11th terminal – 1st, 2nd, 5th, 6th,
9th, 10th terminal
PCU harness (12P) lower-side
connector – GND
1st terminal – GND
2nd terminal – GND
5th terminal – GND
6th terminal – GND
10th terminal – GND
11th terminal – GND
<Standard values>
10 k
or more (No continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 5.
Replace the
PCU wire har-
ness (lower
side).
5
Inspecting the
PCU wire har-
ness (lower
side) for conti-
nuity
1. Using the electrical tester, mea-
sure the resistance between
the terminals of PCU harness
(12P) lower-side connector and
inverter connector.
<Measurement conditions>
—
<Tester connections>
PCU harness (12P) lower-side
connector – Inverter
1st terminal – 23rd terminal
2nd terminal – 24th terminal
5th terminal – 12th terminal
6th terminal – 14th terminal
10th terminal – 13th terminal
11th terminal – 15th terminal
9th terminal – 27th terminal
<Standard values>
1
or less (With continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 6.
Replace the
PCU wire har-
ness (lower
side).
P0A41 (TCC0)
Resolver range Low abnormality
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No