INSPECTION PROCEDURE: P062F (TC41)
1.
Set the starter key to the "LOCK" position.
2.
Connect the diagnosis tool (HINO-DX) to the vehicle.
3.
Set the starter key to the "ON" position.
4.
Clear the malfunction history.
5.
Perform a test run. (accelerate and decelerate running for approxi-
mately 1 hour).
6.
Set the starter key to the "ON" position.
7.
In [Fault Information] on the diagnosis tool screen, check if P062F-
41 is detected.
NO
YES
CHECKLIST: P062F (TC41)
1
Reproduction check [HINO-DX]
SHTS03ZZZ0300299
Is DTC P062F-41 detected?
Replace the inverter.
The inspection is completed.
(Temporary actuation of protection function
due to external noise)
P062F (TC41)
Abnormality in inverter
(abnormality in memory)
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No
1
Reproduction
check [HINO-
DX]
1. Set the starter key to the
"LOCK" position.
2. Connect the diagnosis tool
(HINO-DX) to the vehicle.
3. Set the starter key to the "ON"
position.
4. Clear the malfunction history.
5. Perform a test run. (accelerate
and decelerate running for
approximately 1 hour).
6. Set the starter key to the "ON"
position.
7. In [Fault Information] on the
diagnosis tool screen, check if
P062F-41 is detected.
DTC P062F-
41 is detected:
Go to YES.
DTC P062F-
41 is not
detected: Go
to NO.
Replace the
inverter.
The inspec-
tion is com-
pleted.
(Temporary
actuation of
protection
function due to