HYBRID/TROUBLE SHOOTING
3–336
INSPECTION PROCEDURE: P33B1 (TC64)
1.
Set the starter key to the "LOCK" position.
2.
Remove the HV battery start relay from the relay block.
3.
Using the electrical tester, measure the resistance between the
HV battery start relay terminals.
NO
YES
1.
Using the electrical tester, measure the resistance between the
HV battery start relay connector (relay block) and the ground.
NO
YES
1
Inspecting the HV battery start relay
3
5
1
2
SHTS03ZZZ0300224
Measurement
conditions
Tester
connections
Standard values
—
HV battery start
relay (relay side)
1st terminal
–
2nd terminal
95
–
125
Is the measured value within the range of standard value?
Go to step 2.
Replace the HV battery start relay.
2
Inspecting the PCU wire harness (lower side) for short circuit
VEHICLE GND
SHTS03ZZZ0300225
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
HV battery start
relay connector
1st terminal
–
Ground
10 k
or more
Is the measured value within the range of standard value?
Go to step 3.
Replace the PCU wire harness (lower side).