HYBRID/TROUBLE SHOOTING
3–101
1.
Using the electrical tester, measure the resistance between each
terminal of coolant temperature sensor connector and the ground.
NO
YES
1.
Using the electrical tester, measure the resistance between the
terminals of coolant temperature sensor connector.
NO
YES
2
Inspecting the PCU wire harness (lower side) for short circuit 1
VEHICLE GND
SHTS03ZZZ0300070
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Coolant tempera-
ture sensor con-
nector
1st terminal
–
GND
2nd terminal
–
GND
10 k
or more
Is the measured value within the range of standard value?
Go to step 3.
Replace the PCU wire harness (lower side).
3
Inspecting the PCU wire harness (lower side) for short circuit 2
SHTS03ZZZ0300071
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Coolant tempera-
ture sensor con-
nector
1st terminal
–
2nd terminal
10 k
or more
Is the measured value within the range of standard value?
Go to step 4.