HYBRID/TROUBLE SHOOTING
3–649
1.
Check the BATT OUT(+) terminal and BATT OUT(-) terminal of the
high-voltage J/B (in the battery pack) for failing connection (loose-
ness, wear, or damage).
NO
YES
1.
Remove the PCU top cover.
2.
Check the BATT IN(+) terminal and BATT IN(-) terminal of the
high-voltage J/B (in the battery pack) for failing connection (loose-
ness, wear, or damage).
NO
YES
5
Inspecting the DC high-voltage cable 2
BATT OUT(-)
BATT OUT(+)
SHTS03ZZZ0300421
Is any defect found?
Retighten the terminals.
Replace the terminals if abnormal wear or
melting damage is detected.
Go to step 6.
6
Inspecting the DC high-voltage cable 3
BATT IN(-)
BATT IN(+)
SHTS03ZZZ0300422
Is any defect found?
Retighten the terminals.
Replace the terminals if abnormal wear or
melting damage is detected.
Go to step 7.