HYBRID/TROUBLE SHOOTING
3–294
1.
Connect the PCU harness (24P) connector and the inverter start
relay.
2.
Disconnect the connector of inverter cooling radiator fan.
3.
Set the starter key to the "ON" position.
4.
Using the electrical tester, measure the voltage between the con-
nector terminals of inverter cooling radiator fan.
NO
YES
6
Inspecting the voltage of PCU wire harness (lower side)
SHTS03ZZZ0300200
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
Inverter cooling
radiator fan con-
nector
1st terminal
–
2nd terminal
9 V or more
Is the measured value within the range of standard value?
Go to step 7.
Replace the PCU wire harness (lower side).