HYBRID/TROUBLE SHOOTING
3–189
1.
Disconnect the three-phase cable (U, V, and W terminals) from the
relay terminal block.
2.
Using the electrical tester, measure the resistance between the
terminals of both ends of the three-phase cable on the HV motor
side.
NO
YES
7
Inspecting the continuity of three-phase cable 2
W
V
U
SHTS03ZZZ0300127
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Three-phase cable
on the HV motor
side
U terminal
–
U terminal
V terminal
–
V terminal
W terminal
–
W terminal
Less than 1
Is the measured value within the range of standard value?
Replace the three-phase cable on the
inverter side.
Replace the three-phase cable on the HV
motor side.