52
TLC2100-S16
1837-0700-4852542C
MultiLink/Remote Port
Submenu
This feature allows you to control your VCR through the MultiLink/Remote Port
using a PC or other controlling device. The RS-232 protocol is set in the MultiLink/
Remote Port menu. A list of RS-232 commands follows below.
This submenu sets the protocol for the Remote port and is displayed in the Main Menu:
REMOTE PORT
Exit
Baud: 19200
Parity: None
Mode: 1-Stop
Code: 8-bit ASCII
The following parameters are available with this menu:
• Baud: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400
• Parity: None, Odd, Even
• Mode: 1 Stop, 2 Stop
• Code: 7-Bit ASCII, 8-Bit ASCII
For operational information for remote usage, see the “Appendix B - Remote Control
Feature” section of this manual. Also see the “Rear Panel Functions” and “Installation”
sections of this manual for rear panel interface information.
Most functions of this time-lapse recorder may be controlled from a personal
computer or dumb terminal supplying an asynchronous port.
These commands have been divided into five command sets as listed below.
• Set 1:
Operational Control Commands, (Play, Counter Reset, etc.)
• Set 2:
VCR Extended Status Commands (Tab, Index, Lock, etc.)
• Set 3:
Program Control Function Commands (Program, Previous, Up, Down,
etc.)
• Set 4:
Tape Speed Commands
• Set 5:
Extended Commands ((Date Set, Timer Program, etc.)
Each command is described in the section that follows.
Note:
The recorder remote will respond to commands with (unless otherwise noted):
*
- command accepted, or
?
- command incorrect, does not exist or cannot be performed
Remote Terminal
Interface Commands
1. GND
2. TX (IN)
3. RX (OUT)
4. CTS
5. RTS
7. GND
Pinout for RS232 Port:
13