![Gyyr TLC2100-S16 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/gyyr/tlc2100-s16/tlc2100-s16_operating-instructions-manual_2281271055.webp)
45
TLC2100-S16
1837-0700-4852542C
The RS-232 menu allows access to the submenus used to set the parameters for the
serial port, the ATM text format, and the communication protocol for a remote port.
RS-232
Exit
MP Port
>
MultiLink/Remote Port
>
This menu allows you to access and set parameters for the serial port configurations
and the ATM text format displays.
MP Port
Exit
Configure Serial
>
Address Select
>
Sync to ATM Time
>
ATM Text Formatter
>
The Configure Serial submenu allows you to set the RS-232 port communications
protocol. Both low-level configurations, such as baud, parity and data format, and
high level configurations, such as the ATM interface and network address are set here.
Configure Serial
Exit
Configuration: User
Protocol: BISYNC
Baud: 9600
Parity: None
Mode: SYNC
Code: 8-bit ASCII
D25 Connection: DCE
Device: Generic
See the “Configure Serial Submenu Value Chart” section of this manual for more
information. The Configuration line may be set to User or Auto.
Set to ”Auto” to have system automatically configure the protocol of the RS232 port
(Note: this will operate properly only when you have connected your system to an
ATM interface). The unit will enter the proper settings into this menu.
To set the RS-232 protocol automatically:
• Select “Auto” in the Configuration line.
• Press the PROG. button
• The unit will enter the values automatically in the menu; this may take several
passes.
• The value “User” will be displayed in the menu after auto-configuring is complete.
Important Note:
• If the value “Auto” continues to be displayed in the menu after several passes,
the unit is not able to automatically configure the protocol values. In this case,
you will need to set the values manually. Press the PROG. button, so that you
can select “User” in the Configuration line and then enter all the other values in
this menu.
RS-232 Submenu
MP Port Submenu
Configure Serial
Submenu
Important Note:
For the unit to automatically
configure the protocol of the
RS-232 port, you must be com-
municating with the ATM; that
is, you need to perform one or
more transactions while per-
forming the auto configuration.