42
TLC2100-S16
1837-0700-4852542C
Day (Night) Rec Sequence
Exit
1- 1
2f+
2- 2
2f+
3- 3
2S+
4- 4
2f+
5- 5
2f+
6- 6
2f+
7- 7
2f+
8- 8
2f-
9- 9
2f+
10-10
2f+
11-11
2f+
12-12
2f+
13-13
2f-
14-14
2f+
15-15
2f+
16-16
2f+
Total =
2S
26f
Day (Night) Rec
Sequence Submenu
This menu sets camera sequencing for normal operation (non-alarm mode). This menu
relates to the monitor connected to VCR Out. The menu above displays a typical menu
with cameras present and lost.
This menu is programmed in an identical manner to the Day Sequence Alarm menu;
refer to that section for more information. Note that you cannot set the fields setting
to “0” (zero); you must set zero fields to “L“. Attached cameras will be displayed with
“1f” as a default.
If there is a video loss, it will be displayed in the menu as “-“. “L” indicates a camera
lockout.
The Total line will display the total amount of time in the sequence (that is, the time
of the cameras present) in Seconds and/or Fields.
Day (Night) Spot Sequence
Exit
1- 1 1S+
2- 2 1S-
3- 3 1S+
4- 4 1S+
5- 5 1S+
6- 6 1S+
7- 7 1S+
8- 8 1S+
9- 9 1S-
10-10 1S+
11-11 1S+
12-12 1S+
13-13 1S+
14-14 1S+
15-15 1S+
16-16 1S+
Total =
14S
Day (Night) Spot
Sequence Submenu
Notes:
This menu sets camera sequencing for normal operation (non-alarm mode). This menu
relates to the Spot monitor. The menu above displays a typical menu with cameras
present and lost.
This menu is programmed in an identical manner as the Day Rec Sequence Alarm
menu above; except that only “S” (seconds), “B” (Bypass) and “L” (Lockout) param-
eters are allowed. Default setting is “1S“.