203
which is used when the sytem is being tested, when the system run normally, the parameter
is set to 0, otherwise, there may be the unexpected accidence.
8. K0100, K0101, K0102, K0103, K0104, K0105, K0106, K0107, K0110, K0111
Table 4 PLC external alarm definition
PMC alarm number
A address
Alarm content
1200
A0000
Air pressure check abnormal
1201
A0001
Lubricating check abnormal
1202
A0002
Lubricating motor check
abnormal
1203
A0003
Cooling motor check abnormal
1204
A0004
Chip removal motor check
abnormal
1205
A0005
Pressure oil pump check
abnormal
1206
A0006
Spindle cooling unit check
abnormal
1207
A0007
Machine tool light check
abnormal
1208
A0010
Machine tool control box
1209
A0011
Machine tool bed temperature
check abnormal
1210
A0012
Machine tool vibration check
abnormal
1211
A0013
Pressure oil temperature check
abnormal
1212
A0014
Oil pressure low
1213
A0015
Machine not ready
1214 A0016
Reversed
1215 A0017
Reversed
1216
A0020
Do not rotate the spindle when
the tool releases
1217
A0021
The tool cannot release when
the spindle rotates
1218
A0022
Confirm the tool number when
the tool magazine stops
normally
1219
A0023
The spindle cannot rotate
when the tool magazine is the
infeed tool position
1220
A0024
Spindle tool clamping
abnormal
1221 A0025
Spindle
tool releasing check
abnormal
Содержание 218M
Страница 3: ...GSK 218M CNC System Connection and PLC Manual...
Страница 15: ...GSK218M CNC System Connection and PLC Manual 12 Volume one Programming...
Страница 70: ...GSK218M CNC System Connection and PLC Manual 67 Volume Two Function...
Страница 140: ...GSK218M CNC System Connection and PLC Manual 137 Volume Three Operation...
Страница 160: ...GSK218M CNC System Connection and PLC Manual 157 Volume Four Connection...
Страница 163: ...GSK218M CNC System Connection and PLC Manual 160 2 Side view 3 Overlook Without PC2 power supply...