GSK218M CNC System Connection and PLC Manual
41
destination for JMPB functional instruction.
Note: one Lx label is only specified one time with LBL. Otherwise, the system alarms.
Format:
Parameter:
Lx: specifies the label of the jump destination. Label number range: 0
~
99
Example:
5.10 TMR
(
timer
)
Function:
This is an on-delay timer.
Format:
Control condition:
ACT=0: turns off the timer relay.
ACT=1: initiates the timer. i.e. timing from 0.
Detailed functions:
JMPB L33
LBL L33
JMPB L33
LBL
Label
ACT
TMR
TIMER number
ACT
Address.b
TIME
(
W
)