Format:
COM execution range
Control condition:
ACT=0: The specified number of coils or the coils within the region specified are
unconditionally turned off (W=0).
ACT=1: No processing is performed.
Note:
1. In the range specified with a COM instruction, no additional COM instructin can be
specified.
2. the coil for WRT.NOT in the range specified with a COM instruction is unditionally set to 1
when COM ACT=0.
3. do not use the function block between COM and COME, otherwise, the system will alarm.
5.15 COME (common line control end)
Function:
The
instruction
reports the division in the region specification of the common line control
instruction
(COM). This
instruction
cannot be used alone. It must be used together with
the COM instruction.
Format:
(
W
)
(
W
)
COME
COM
ACT
COME