GSK218M CNC System Connection and PLC Manual
173
200mA.
②
When the output is ON and the current is 200mA, the saturation voltage is 1.6V and the
typical value is 1V .
③
When the output is OFF, the withstand voltage including instantaneous voltage is below
24+20%.
④
When the output is OFF, the leak current is below 100
μ
A.
b
)
Output loop
:
CNC side
0V
0V
Relay
+24V
Machine side
0V
Fig. 3-3-1-1
The output signals of the CNC are provided by Darlington pipe and Darlington pipe is
conducted when the output is enabled. Except for TL-, TL+, SPZD are pulse signals, other
outputs are the level signal and their common terminal is 24V.
3.3.2 Ouput signal interface definition
XS40 output 1
Pin Markign
Label
1 DO00
Y0.0
14 DO01 Y0.1
2 DO02
Y0.2
15 DO03 Y0.3
17 DO04 Y0.4
5 DO05
Y0.5
18 DO06 Y0.6
6 DO07
Y0.7
8 DO08
Y1.0
21 DO09 Y1.1
9 DO10
Y1.2
22 DO11 Y1.3
24 DO12 Y1.4
12 DO13 Y1.5
25 DO14 Y1.6
Содержание 218M
Страница 3: ...GSK 218M CNC System Connection and PLC Manual...
Страница 15: ...GSK218M CNC System Connection and PLC Manual 12 Volume one Programming...
Страница 70: ...GSK218M CNC System Connection and PLC Manual 67 Volume Two Function...
Страница 140: ...GSK218M CNC System Connection and PLC Manual 137 Volume Three Operation...
Страница 160: ...GSK218M CNC System Connection and PLC Manual 157 Volume Four Connection...
Страница 163: ...GSK218M CNC System Connection and PLC Manual 160 2 Side view 3 Overlook Without PC2 power supply...