3. regulate again T009 time.
Alarm information: 1222 the spindle unit temperature check is abnormal
Fault cause: defined by customer
Troubleshooting: no
Alarm information: 1223 the spindle speed is abnormal
Fault cause: defined by customer
Troubleshooting: no
Alarm information: 1224 the spindle motor enabling check is abnormal.
Fault cause: defined by customer
Troubleshooting: no
Alarm information: 1224 the spindle motor enabling check is abnormal.
Fault cause: when the tool is clamped(i.e.Y2.1=1), the tool magazine clamp check switch (X2.5)
is not closed during the time set by T013.
Troubleshooting: 1. the spindle driver or spindle encoder is normal.
2. check whether Y2.1 outputs.
3. regulate again T013 time.
Alarm information: 1226 the spindle gear change is abnormal
Fault cause: defined by customer
Troubleshooting: no
Alarm information: 1227 the tool magazine which is not in the origin point cannot rotate.
Fault cause: the tool magazine is not in the retraction position and Z axis is not in the origin point,
or press “MAG. CCW” or “MAG. CW”, the alarm appears.
Troubleshooting: the tool magazine returns the retraction position or Z axis returns to the origin
point.
Alarm information: 1228 the tool magazine cannot execute the cycle start when it is in the
infeed position
Fault cause: when the tool magazine is not in the retraction position, or press “CYCLE START” ,
the alarm appears.
Troubleshooting: the tool magazine returns the retraction position
Содержание 218M
Страница 3: ...GSK 218M CNC System Connection and PLC Manual...
Страница 15: ...GSK218M CNC System Connection and PLC Manual 12 Volume one Programming...
Страница 70: ...GSK218M CNC System Connection and PLC Manual 67 Volume Two Function...
Страница 140: ...GSK218M CNC System Connection and PLC Manual 137 Volume Three Operation...
Страница 160: ...GSK218M CNC System Connection and PLC Manual 157 Volume Four Connection...
Страница 163: ...GSK218M CNC System Connection and PLC Manual 160 2 Side view 3 Overlook Without PC2 power supply...