GSK218M CNC System Connection and PLC Manual
46
1
:
2 bytes
2
:
4 bytes
3
:
8 bytes
4
:
16 bytes
5
:
32 bytes
6
:
64 bytes
7
:
128 bytes
8
:
256 bytes
S1
:
Data in the conversion data table can be taken out by specifying the table number.
The address specifying the table number is called conversion input data address,
and 1-byte memor is required from the specified address.
S2
:
Conversion data output address. Memory of the byte length specified in the format
designation is necessary from the specified address.
Output:
If there are any abnormality when executing the CODB instruction, W=1, and error will be
output.
Note: Size of the conversion data table is maximum 256. This conversion data table is
programmed between the parameter conversion data output address of this instruction and
the error output(W).
5.14 COM (common line control)
Function:
This function can be used for specifying the number of coil only on the PMC-SB/SC. If the common
line end instruction is not specified, the system will alarm.