GSK218M CNC System Connection and PLC Manual
56
1.When S1 is the constant 5 and S2 is R60
,
R60=00000101,R61=00000101
2.When S1 is the constant 5 and S2 is D60
,
D60=1285
3.When S1 is the constant 500 and S2 is D60
,
D60=62708
4.When S1 is the constant D50 and S2 is D60
,
D60=D50
5.23 XMOV
(
Binary index data transfer
)
Function:
This function instruction instructs reading and rewriting of data in the data. The number of
data(table capacity) in the data table can be specified by specifying the address, thus allowing
change in table capacity even after writing the sequence program in the ROM.
Format:
Control condition:
Specify the reading ro rewriting (RW)
RW=0
:
data is read from the data table.
RW=1
:
data is written in the data table.
Reset
(
RST
)
RST=0
:
release reset.
RST=1
:
reset W=0.
Execution instruction (ACT):
ACT
=
0 : The XMOV instruction is not executed. W does not change.
ACT
=
1 : The XMOV instruction is executed.
Parameter:
Length
:
Specify the data long.
1
:
1-byte long data.
2
:
2-byte long data.
XMOV
Length
format
S1
Number
of data of
the data
table(table
capacity)
S2
Data table
heading
address
S3
Address
storing input
/output data
S4
Address storing
table internal
number
RW
RST
(
W
)
ACT
Содержание 218M
Страница 3: ...GSK 218M CNC System Connection and PLC Manual...
Страница 15: ...GSK218M CNC System Connection and PLC Manual 12 Volume one Programming...
Страница 70: ...GSK218M CNC System Connection and PLC Manual 67 Volume Two Function...
Страница 140: ...GSK218M CNC System Connection and PLC Manual 137 Volume Three Operation...
Страница 160: ...GSK218M CNC System Connection and PLC Manual 157 Volume Four Connection...
Страница 163: ...GSK218M CNC System Connection and PLC Manual 160 2 Side view 3 Overlook Without PC2 power supply...