![Grundig GD-RT-AC3004N Скачать руководство пользователя страница 208](http://html1.mh-extra.com/html/grundig/gd-rt-ac3004n/gd-rt-ac3004n_user-manual_2272749208.webp)
208
1)
If not, please install the compatible HDD.
Note:
Please refer to the “Quick Operation Guide” for the HDD installation steps.
2)
If you do not want to install a HDD, select
Menu>Configuration > Exceptions
and uncheck
the Audible Warning checkbox <HDD Error>.
2.
Verify that the HDD is initialized.
1)
Select
Menu>HDD>General
.
2)
If the status of the HDD is <Uninitialized>, please check the checkbox of the corresponding
HDD and click the <Init> button.
3.
Verify that the HDD is detected or is in good condition.
1)
Select
Menu>HDD>General
.
2)
If the HDD is not detected or the status is <Abnormal>, please replace the dedicated HDD
according to the requirement.
4.
Check if the fault is solved by following steps 1 to 3.
1)
If it is solved, finish the process.
2)
If not, please contact the engineer from our company to continue the process.
Live view stuck when video outputs locally.
Possible Reasons:
—
The frame rate has not reached the real-time frame rate.
Steps:
1.
Check the parameters of <Main Stream (Continuous)> and <Main Stream (Event)>.
Select
Menu > Record > Parameters > Record
and set the resolution for <Main Stream
(Event)> to the same as the one for <Main Stream (Continuous)>.
2.
Verify that the frame rate is a real-time frame rate.
Select
Menu > Record > Parameters > Record
and set the <Frame Rate> to <Full Frame>.
3.
Check if the fault is solved by following the above steps.
If it is solved, finish the process.
If not, please contact the engineer from our company to continue the process.
When using the device to get the live view audio, there is no sound, is too much noise or
the volume is too low.
Possible Reasons:
—
The cable between the pickup and the camera is not well-connected; impedance
mismatches or incompatible.
—
The stream type is not set as <Video & Audio>.