![Grundig GD-RT-AC3004N Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/grundig/gd-rt-ac3004n/gd-rt-ac3004n_user-manual_2272749137.webp)
137 ENGLISH
10.10 Parking Detection
This function may not be available in every recorder model.
The Parking Detection function detects illegal parking in places such as on highways, in one-way
streets, etc. and a series of actions can be taken when the alarm is triggered.
Note:
‒
Please refer to
Chapter 9.4 Intrusion Detection
for operating steps to configure the parking
detection.
‒
The <Threshold> [5s-20s] in the <Rule Settings> defines the time for how long the vehicle is
parking in the region. If you set the value to 10, then the alarm is triggered after the vehicle
has been staying in the region for 10 seconds.
‒
Up to 4 rules can be configured.
10.11 Unattended Baggage Detection
This function may not be available in every recorder model.
The Unattended Baggage Detection function detects the objects left behind in the pre-defined
region such as baggage, purses, dangerous materials, etc. and a series of actions can be taken
when the alarm is triggered.
Note:
‒
Please refer to
Chapter 9.4 Intrusion Detection
for operating steps to configure the Unattended
Baggage Detection.
‒
The <Threshold> [5s-20s] in the <Rule Settings> defines the length of time for which objects
are left behind in the region. If you set the value to 10, then the alarm is triggered after the
object is left and stayed in the region for 10 second. And the <Sensitivity> defines the degree
of similarity to the background image. Usually, when the sensitivity is high, a very small object
left in the region can trigger the alarm.
‒
Up to 4 rules can be configured.
10.12 Object Removal Detection
This function may not be available in every recorder model.
The Object Removal Detection function detects objects that are removed from the pre-defined
region, such as exhibits on display and a series of actions can be taken when the alarm is triggered.
Note:
‒
Please refer to
Chapter 9.4 Intrusion Detection
for operating steps to configure the Object
Removal Detection.
‒
The <Threshold> [5s-20s] in the <Rule Settings> defines the length of time for which the
objects are removed from the region. If you set the value to 10, then the alarm is triggered
after the object disappears from the region for 10 seconds. And the <Sensitivity> defines the