EF.1-48
Criterion to flashing codes and the mounting torque of parts &components within
M1.5.4 system
1
.
List of flashing codes within M1.5.4 system
S.N.
Name of failure information
Flashing code
Type of
failure
Fault
indicator
lamp
1
Failure with knock sensor
zero test status
1 1 1
2 No
failure.
11
-
-
3
The temperature of air-conditioner evaporator is
unreliable.
13 1 0
4
The signal of throttle position sensor is unreliable.
14
1
1
5
The signal of knock sensor is unreliable.
15
2
1
6
The signal of inlet-air pressure sensor is unreliable.
16
1
1
7
The signal of oxygen sensor is unreliable.
17
1
1
8
The signal of inlet-air temperature sensor is unreliable.
18
1
1
9
The signal of cooling-fluid temperature sensor is
unreliable.
19 1 1
10
Injector -failure with the driving stage of cylinder 4
21
1
1
11
Injector -failure with the driving stage of cylinder 1
22
1
1
12
Injector -failure with the driving stage of cylinder 2
23
1
1
13
Injector -failure with the driving stage of cylinder 3
24
1
1
14
Failure with the driving stage of carbon-canister control
valve
25 1 1
15
The air /fuel ratio, and the control &repair coefficient
are unreliable.
31 2 0
16
The engine is running out of Max. rotating-speed.
33
2
0
17
Failure with the electronic control unit.
34
2
1
18
The air /fuel ratio to control the addition modification
coefficient
The scope of idle-speed plays a role
35 2 0
19
The air /fuel ratio to control the multiplication
modification coefficient The scope of idle-speed plays a
role
36 2 0
20
A self-learning of addition modification (for air leakage
amount) controlled by the air /fuel ratio
37 2 0
21
The accumulator voltage is unreliable.
38
2
0
22
The signal of vehicle speed is unreliable.
41
2
0
23
Failure with the cooling-fan relay.
42
1
1
24
The signal to determine cylinder is unreliable.
43
2
0
25
Failure with the driving stage of fault indicator lamp.
45
1
0
26
Failure with the driving stage 1
of step motor-EWD coil 1
61 1 1
27
Failure with the driving stage 2
of step motor –EWD coil 2
62 1 1
Type of failure
:
1
”
denotes an open circuit, or a short circuit to ground, or a short circuit to power supply; and
2
”
denotes the signal out of limit.
Fault indicator lamp
:
1
”
denotes lighting, and
0
”
denotes off.
Criterion to flashing codes and the mounting torque of parts &components within
M1.5.4 system
ProCarManuals.com
Содержание GW491QE
Страница 1: ...ProCarManuals com ...
Страница 120: ...EF 2 35 attached figure V Delphi engine management system troubleshooting and common failure ProCarManuals com ...
Страница 121: ...EF 2 36 Attached figure VI Delphi engine management system troubleshooting and common failure ProCarManuals com ...
Страница 122: ...EF 2 37 Attached figure VII Delphi engine management system troubleshooting and common failure ProCarManuals com ...
Страница 123: ...EF 2 38 Attached figure VIII Delphi engine management system troubleshooting and common failure ProCarManuals com ...
Страница 190: ...IG 1 Ignition system ProCarManuals com ...
Страница 218: ...CL 1 C l u t c h ProCarManuals com ...
Страница 222: ...ProCarManuals com ...