Description of the parameter.
3
Depends on the type of parameter:
●
Numeric parameter:
displays the numeric value of the parameter, in the
format required, and unit of measurement (figure A).
●
Binary selection:
the parameter may assume only 2 states, indicated as
OFF-ON or 0 - 1 (figure B).
●
LINK type parameter:
displays the description of the parameter set from the
selection list (figure C).
●
ENUM type parameter:
displays the description of the selection (figure D)
●
Command:
displays the method of execution of the command (figure E)
4
In this position, the following may be displayed:
●
Numeric parameter:
displays the default, minimum and maximum values
of the parameter. These values are displayed in sequence pressing the ► key
(figure A).
●
LINK type parameter:
displays the number (PAR) of the parameter set (fig-
ure C) .
●
ENUM type parameter:
displays the numeric value corresponding to the cur-
rent selection (figure D).
●
Command:
in the case of an error in the command, indicates that ESC must
be pressed to terminate the command (figure G).
●
Messages and error conditions
(figure F):
Param read only
attempt to modify a read-only parameter
Password active
the parameter protection password is active
Drive enabled
attempt to modify a non-modifiable parameter with the drive enabled
Input value too high
the value entered too high
Input value too low
the value entered too low
Out of range
attempt to insert a value outside the min. and max. limits
6.2.3 Scanning of the parameters
T+
T-
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 1
PA R :
2 5 0
Output current
+
0 . 3
A
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 2
PA R :
2 5 2
Out ut volta e
p
g
-
1
V
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 2 2
PA R :
1 4 0 0
Digital out ut X mon
p
0
. . .
. . .
6.2.4 List of the last parameters modified
Pressing the
CUST
key, a list containing the last 10 parameters modified is ac-
cessed. One parameter at a time is displayed and the list can be scrolled using
the ▲ and ▼ keys.
To exit this list, press the ► key.
6.2.5 “Goto parameter” function
Pressing the
CUST
key twice, or once if already in the “List of modified param-
eters”, the “Goto parameter” is activated.