ADV200 WA • Quick start up guide - Specification and installation
• Safety Card
Integrated on board as the 4th option (ADV200 WA-...-SI models), the EXP- SFTy card
allows the motor to be disabled without the use of a safety contactor on the drive output,
guaranteeing compliance to the directive for machine safety EN61800-5-2 SIL3.
The EXP- SFTy card is integrated as standard in the master inverter of 500 to 1200 kW
parallel versions.
• Serial Line
Integrated standard RS485 serial line with Modbus RTU protocol, for peer-to-peer or
multidrop connections (with OPT-RS485-ADV card).
• Back-Up Supply
ADV200 WA can be supplied through an ex24Vdc supply in order to be kept ac-
tive in case of mains input loss, ensuring in this situation the operation of all monitoring
functions, programming and any connected fieldbus network.
• Cables shield
OMEGA clamp to grounding 360° of shielded cables.