60
ADV200 WA • Quick start up guide - Specification and installation
LED’s meaning:
T+
the LED is lit, when the drive operates with a positive torque
T-
the LED is lit, when the drive operates with a negative torque
EN
the LED is lit, when the drive is enabled
LOC
The led is lit when the drive is in local mode and OFF when in remote
mode.
Ilim
the LED is lit, when the drive operates at a current limit. During normal
functioning, this led is OFF.
n=0
the LED is lit; it signals zero speed
AL
the LED is lit; it signals a trip
6.2 Navigation
6.2.1 Scanning of the first and second level menus
T+
T-
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
T+
T-
EN
LOC
ILim
n:0
AL
27 MACRO
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
T+
T-
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
T+
T-
EN
LOC
ILim
n:0
AL
26.01 PID 1 REFERENCES
26.02 PID 1
26.03 PID 2 REFERENCES
26.04 PID 2
T+
T-
EN
LOC
ILim
n:0
AL
23 COMMUNICATION
24 ALARM CONFIG
25 ALARM LOG
26 PROCESS
1st level
2nd level
(*)
(*) This example is visible only in
Export
mode (see
paragraph 6.5.2
).
6.2.2 Display of a parameter
T+
T-
EN
LOC
ILim
n:0
AL
T+
T-
EN
LOC
ILim
n:0
AL
T+
T-
EN
LOC
ILim
n:0
AL
2
1 3 . 0 5
PA R : 1 3 3 0
Dig out 1 inversion
1 6 . 0 1
PA R : 2 0 0 0
Rated volta e
g
+
400
V
0 5 . 0 4
PA R :
6 1 0
Ram ref 1 src
p
Mlt ref out mon
1
3
4
Def:
+400
A
B
C
T+
T-
EN
LOC
ILim
n:0
AL
T+
T-
EN
LOC
ILim
n:0
AL
T+
T-
EN
LOC
ILim
n:0
AL
2
0 4 . 0 1
PA R :
5 5 0
Save arameters
p
0 4 . 0 2
PA R :
5 5 2
Regulation mode
V / f c o n t r o l
0 1 . 0 1
PA R :
2 5 0
Output current
+
0 . 3
A
1
3
4
Value:
0
D
E
F
ON
Value:
2034
Press E to execute
Param read only
T+
T-
EN
LOC
ILim
n:0
AL
2
Autotune
1
3
4
Error code:
1
G
Press ESC to exit
1
Position of the parameter in the menu structure (in figure A, 16.01);
number of the parameter (in figure A, PAR: 2000).