PRODUCT DESCRIPTION
GEK-106273L
MIF Digital Feeder Protection
6-43
50PL pickup
50PL function pickup
50NL pickup
50NL function pickup
51P pickup
51P function pickup
51N pickup
51N function pickup
49 Alarm
49 function pickup
Pickup
Pickup of any of the above mentioned functions
50Ha virtual trip
Virtual trip of Phase A 50PH unit
50Hb virtual trip
Virtual trip of Phase B 50PH unit
50Hc virtual trip
Virtual trip of Phase C 50PH unit
50La virtual trip
Virtual trip of Phase A 50PL unit
50Lb virtual trip
Virtual trip of Phase B 50PL unit
50Lc virtual trip
Virtual trip of Phase C 50PL unit
51 a virtual trip
Virtual trip of Phase A 51P unit
51 b virtual trip
Virtual trip of Phase B 51P unit
51 c virtual trip
Virtual trip of Phase C 51P unit
50PH virtual trip
Trip condition for 50PH function exists
50NH virtual trip
Trip condition for 50NH function exists
50PL virtual trip
Trip condition for 50PL function exists
50NL virtual trip
Trip condition for 50NL function exists
51P virtual trip
Trip condition for 51P function exists
51N virtual trip
Trip condition for 51N function exists
49 virtual trip
Trip condition for 49 function exists
General virtual trip
Any virtual trip of the above mentioned functions
Input 1
Digital input 1
Input 2
Digital input 2
Breaker failure to open
Output of the breaker failure to open function, when it is enabled
Breaker status
When BF function is enabled and breaker is connected to input1/2
I2 Alarm
Output of the I
2
counter function
Cold load pickup
Output of the Cold load pickup function, when it is enabled
E2prom failure
Active when a failure is detected in e2prom management
User settings
This function is green when the default settings are active and red
when the user’s settings are active
Protection
Active when the relay is in service and at least one function has trip
enabled
CLOSE BREAKER
Active with the “Close Breaker” operation
ACTIVE TABLE
T1 or T2
Local/Remote
It’s local when the HMI is inside the MAIN SETTINGS or
ADVANCED SETTINGS menu or OPERATIONS menu
When trip conditions exist for a protection unit, the relay operates a virtual trip of this unit. If it is not disabled by
setting or Digital Input, the trip occurs.
Содержание GEK-106273L
Страница 19: ...GETTING STARTED 1 12 MIF Digital Feeder Protection GEK 106273L ...
Страница 95: ...SETTINGS 5 38 MIF Digital Feeder Protection GEK 106273L ...
Страница 101: ...I O CONFIGURATION 6 44 MIF Digital Feeder Protection GEK 106273L ...
Страница 127: ...KEYPAD AND DISPLAY 8 26 MIF Digital Feeder Protection GEK 106273L ...
Страница 147: ...INSTALLATION AND MAINTENANCE 10 2 MIF Digital Feeder Protection GEK 106273L ...
Страница 154: ...ANNEX 1 THERMAL IMAGE UNIT GEK 106273L MIF Digital Feeder Protection 11 7 Figure A 1 1 THERMAL CURVE FOR τ1 3 MINUTES ...
Страница 155: ...ANNEX 1 THERMAL IMAGE UNIT 11 8 MIF Digital Feeder Protection GEK 106273L Figure A 1 2 THERMAL CURVES FOR τ1 3 MIN ...
Страница 199: ...ANNEX 5 HARMONIC FILTERING 15 4 MIF Digital Feeder Protection GEK 106273L ...