GE Power Management
745 Transformer Management Relay
8-69
8 COMMUNICATIONS
8.3 MODBUS MEMORY MAP
8
CALIBRATION
DATA
continued
5113
Winding 1/2 Ground Current x8 Offset
–100 to +100
1
---
F4
0
5114
Winding 1/2 Ground Current x8 Gain
0 to 20000
1
---
F1
15556
5115
Winding 2 Phase A Current x1 Offset
–100 to +100
1
---
F4
0
5116
Winding 2 Phase A Current x1 Gain
0 to 20000
1
---
F1
15556
5117
Winding 2 Phase A Current x8 Offset
–100 to +100
1
---
F4
0
5118
Winding 2 Phase A Current x8 Gain
0 to 20000
1
---
F1
15556
5119
Winding 2 Phase B Current x1 Offset
–100 to +100
1
---
F4
0
511A
Winding 2 Phase B Current x1 Gain
0 to 20000
1
---
F1
15556
511B
Winding 2 Phase B Current x8 Offset
–100 to +100
1
---
F4
0
511C
Winding 2 Phase B Current x8 Gain
0 to 20000
1
---
F1
15556
511D
Winding 2 Phase C Current x1 Offset
–100 to +100
1
---
F4
0
511E
Winding 2 Phase C Current x1 Gain
0 to 20000
1
---
F1
15556
511F
Winding 2 Phase C Current x8 Offset
–100 to +100
1
---
F4
0
5120
Winding 2 Phase C Current x8 Gain
0 to 20000
1
---
F1
15556
5121
Winding 2/3 Ground Current x1 Offset
–100 to +100
1
---
F4
0
5122
Winding 2/3 Ground Current x1 Gain
0 to 20000
1
---
F1
15556
5123
Winding 2/3 Ground Current x8 Offset
–100 to +100
1
---
F4
0
5124
Winding 2/3 Ground Current x8 Gain
0 to 20000
1
---
F1
15556
5125
Winding 3 Phase A Current x1 Offset
–100 to +100
1
---
F4
0
5126
Winding 3 Phase A Current x1 Gain
0 to 20000
1
---
F1
15556
5127
Winding 3 Phase A Current x8 Offset
–100 to +100
1
---
F4
0
5128
Winding 3 Phase A Current x8 Gain
0 to 20000
1
---
F1
15556
5129
Winding 3 Phase B Current x1 Offset
–100 to +100
1
---
F4
0
512A
Winding 3 Phase B Current x1 Gain
0 to 20000
1
---
F1
15556
512B
Winding 3 Phase B Current x8 Offset
–100 to +100
1
---
F4
0
512C
Winding 3 Phase B Current x8 Gain
0 to 20000
1
---
F1
15556
512D
Winding 3 Phase C Current x1 Offset
–100 to +100
1
---
F4
0
512E
Winding 3 Phase C Current x1 Gain
0 to 20000
1
---
F1
15556
512F
Winding 3 Phase C Current x8 Offset
–100 to +100
1
---
F4
0
5130
Winding 3 Phase C Current x8 Gain
0 to 20000
1
---
F1
15556
5131
Voltage Input
×
1 Offset
–100 to +100
1
---
F4
0
5132
Voltage Input
×
1 Gain
0 to 20000
1
---
F1
1412
5133
Voltage Input
×
8 Offset
–100 to +100
1
---
F4
0
5134
Voltage Input
×
8 Gain
0 to 20000
1
---
F1
1412
5135
Tap Changer Input Low Offset
–600 to +600
1
---
F4
0
5136
Tap Changer Input Low Gain
0 to 10000
1
---
F1
5779
5137
Tap Changer Input High Offset
–600 to +600
1
---
F4
0
5138
Tap Changer Input High Gain
0 to 1000
1
---
F1
578
Table 8–6: 745 MEMORY MAP (Sheet 53 of 57)
GROUP
ADDR
(HEX)
DESCRIPTION
RANGE
STEP
VALUE
UNITS
FORMAT
CODE
FACTORY
DEFAULT
Содержание 745 TRANSFORMER MANAGEMENT RELAY
Страница 30: ...2 8 745 Transformer Management Relay GE Power Management 2 3 SECURITY 2 GETTING STARTED 2 ...
Страница 150: ...5 100 745 Transformer Management Relay GE Power Management 5 10 INVERSE VOLTS PER HERTZ CURVES 5 SETPOINTS 5 ...
Страница 210: ...7 36 745 Transformer Management Relay GE Power Management 7 2 BLOCK DIAGRAMS 7 SCHEME LOGIC 7 ...
Страница 322: ...9 12 745 Transformer Management Relay GE Power Management 9 3 USING 745PC 9 745 PC SOFTWARE 9 ...
Страница 392: ...11 24 745 Transformer Management Relay GE Power Management 11 1 COMMISSIONING SUMMARY 11 SETPOINT TABLES 11 ...
Страница 396: ...A 4 745 Transformer Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 398: ...B 2 745 Transformer Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 400: ...C 2 745 Transformer Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 406: ...vi 745 Transformer Management Relay GE Power Management ...
Страница 407: ...GE Power Management 745 Transformer Management Relay NOTES ...