745 Transformer Management Relay
GE Power Management
1.1 INTRODUCTION
1 PRODUCT OVERVIEW
1
1.1.2 SUMMARY OF PROTECTION FEATURES
SYMBOL
COMMON PROTECTION ELEMENT
SYMBOL
WINDING 2 PROTECTION ELEMENT
59/81-1
Volts-Per-Hertz 1
250/46
Negative Sequence Instantaneous O/C
59/81-2
Volts-Per-Hertz 2
251/46
Negative Sequence Time O/C
81U-1
Underfrequency 1
250P1
Phase Instantaneous O/C 1
81U-2
Underfrequency 2
250P2
Phase Instantaneous O/C 2
81U-R1
Frequency Decay Rate 1
250N1
Neutral (3I
0
) Instantaneous O/C 1
81U-R2
Frequency Decay Rate 2
250N2
Neutral (3I
0
) Instantaneous O/C 2
81U-R3
Frequency Decay Rate 3
250G1
Ground Instantaneous O/C 1
81U-R4
Frequency Decay Rate 4
250G2
Ground Instantaneous O/C 2
81-H5
5th Harmonic Level
251P
Phase Time O/C
81O
Overfrequency
251N
Neutral (3I
0
) Time O/C
87
Differential (Percent)
251G
Ground Time O/C
50/87
Instantaneous Differential
287TG
Ground Differential (
Restricted Ground Fault
)
AN-1
Analog Input Level 1
2THD
Total Harmonic Distortion Level
AN-2
Analog Input Level 2
2AD
Current Demand
Insulation Aging
– Aging Factor
– Hottest Spot Limit
– Total Accumulated Life
Tap Changer Monitor
SYMBOL
WINDING 1 PROTECTION ELEMENT
SYMBOL
WINDING 3 PROTECTION ELEMENT
150/46
Negative Sequence Instantaneous O/C
350/46
Negative Sequence Instantaneous O/C
151/46
Negative Sequence Time O/c
351/46
Negative Sequence Time O/c
150P1
Phase Instantaneous O/C 1
350P1
Phase Instantaneous O/C 1
150P2
Phase Instantaneous O/C 2
350P2
Phase Instantaneous O/C 2
150N1
Neutral (3I
0
) Instantaneous O/C 1
350N1
Neutral (3I
0
) Instantaneous O/C 1
150N2
Neutral (3I
0
) Instantaneous O/C 2
350N2
Neutral (3I
0
) Instantaneous O/C 2
150G1
Ground Instantaneous O/C 1
351P
Phase Time O/C
150G2
Ground Instantaneous O/C 2
351N
Neutral (3I
0
) Time O/C
151P
Phase Time O/C
351G
Ground Time O/C
151N
Neutral (3I
0
) Time O/C
387TG
Ground Differential (
Restricted Ground Fault
)
151G
Ground Time O/C
3THD
Total Harmonic Distortion Level
187TG
Ground Differential (
Restricted Ground Fault
)
3AD
Current Demand
1THD
Total Harmonic Distortion Level
1AD
Current Demand
Содержание 745 TRANSFORMER MANAGEMENT RELAY
Страница 30: ...2 8 745 Transformer Management Relay GE Power Management 2 3 SECURITY 2 GETTING STARTED 2 ...
Страница 150: ...5 100 745 Transformer Management Relay GE Power Management 5 10 INVERSE VOLTS PER HERTZ CURVES 5 SETPOINTS 5 ...
Страница 210: ...7 36 745 Transformer Management Relay GE Power Management 7 2 BLOCK DIAGRAMS 7 SCHEME LOGIC 7 ...
Страница 322: ...9 12 745 Transformer Management Relay GE Power Management 9 3 USING 745PC 9 745 PC SOFTWARE 9 ...
Страница 392: ...11 24 745 Transformer Management Relay GE Power Management 11 1 COMMISSIONING SUMMARY 11 SETPOINT TABLES 11 ...
Страница 396: ...A 4 745 Transformer Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 398: ...B 2 745 Transformer Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 400: ...C 2 745 Transformer Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 406: ...vi 745 Transformer Management Relay GE Power Management ...
Страница 407: ...GE Power Management 745 Transformer Management Relay NOTES ...