6-24
745 Transformer Management Relay
GE Power Management
6.8 FLASH MESSAGES
6 ACTUAL VALUES
6
yy
OUT OF RANGE –
yy
VALUE NOT STORED
This flash message is displayed in response to pressing
while on a
setpoint message with a numerical value. The edited value was either less
than the minimum or greater than the maximum acceptable value for this
setpoint and, as a result, was not stored.
yy
PLEASE ENTER A
yy
NON-ZERO PASSCODE
This flash message is displayed while changing the passcode from the
setpoint
S1 745 SETUP/PASSCODE/CHANGE PASSCODE
. An attempt was made to
change the passcode to
0
when it was already
0
.
yy
PRESS [ENTER] TO
yy
ADD AS DEFAULT
This flash message is displayed for 5 seconds in response to pressing the
decimal key followed by
while displaying any setpoint or actual value
message except the
S1 745 SETUP/DEFAULT MESSAGES/SELECTED DEFAULTS
setpoints. Pressing
again while this message is displayed adds the
setpoint or actual value message to the default list.
yy
PRESS [ENTER] TO
yy
BEGIN TEXT EDIT
This flash message is displayed in response to pressing
or
while on a setpoint message with a text entry value. The
key must first be pressed to begin editing.
yy
PRESS [ENTER] TO
yy
REMOVE MESSAGE
This flash message is displayed for 5 seconds in response to pressing the
decimal key followed by
while displaying one of the selected default
messages in
S1 745 SETUP/DEFAULT MESSAGES/SELECTED DEFAULTS
. Pressing
again while this message is displayed removes the default message
from the list.
yy
PRESSED KEY
yy
IS INVALID HERE
This flash message is displayed in response to any pressed key that has no
meaning in the current context.
yy
RESETTING LATCHED
yy
CONDITIONS
This flash message is displayed in response to pressing
when the
relay is in local mode. All active targets for which the activating condition is
no longer present will be cleared.
yy
SETPOINT ACCESS
yy
DENIED (PASSCODE)
This flash message is displayed in response to pressing
while on any
setpoint message. Setpoint access is restricted because the programmed
passcode has not been entered to allow access.
yy
SETPOINT ACCESS
yy
DENIED (SWITCH)
This flash message is displayed in response to pressing
while on any
setpoint message. Setpoint access is restricted because the setpoint access
terminals have not been connected.
yy
SETPOINT ACCESS
yy
IS NOW ALLOWED
This flash message is displayed in response to entering the programmed
passcode at the
S1 745 SETUP/PASSCODE/ALLOW SETPOINT WRITE ACCESS
setpoint. The command to allow write access to setpoints has been
successfully executed and setpoints can be changed and entered.
yy
SETPOINT ACCESS
yy
IS NOW RESTRICTED
This flash message is displayed in response to correctly entering the
programmed passcode at
S1 745 SETUP/PASSCODE/RESTRICT SETPOINT WRITE
ACCESS?
. The command to restrict access to setpoints has been successfully
executed and setpoints cannot be changed.
yy
INVALID SERIAL
yy
NUMBER
This flash message is displayed when an attempt is made to upgrade
installed options and the 745 detects an invalid serial number.
yy
PASSCODE VALID -
yy
OPTIONS ADJUSTED
This flash message is displayed when an attempt to upgrade an option was
successful.
E N TE R
E N T E R
E N T E R
V AL U E
V AL U E
E N TE R
E N TE R
E N TE R
R E S ET
E N T E R
E N TE R
Содержание 745 TRANSFORMER MANAGEMENT RELAY
Страница 30: ...2 8 745 Transformer Management Relay GE Power Management 2 3 SECURITY 2 GETTING STARTED 2 ...
Страница 150: ...5 100 745 Transformer Management Relay GE Power Management 5 10 INVERSE VOLTS PER HERTZ CURVES 5 SETPOINTS 5 ...
Страница 210: ...7 36 745 Transformer Management Relay GE Power Management 7 2 BLOCK DIAGRAMS 7 SCHEME LOGIC 7 ...
Страница 322: ...9 12 745 Transformer Management Relay GE Power Management 9 3 USING 745PC 9 745 PC SOFTWARE 9 ...
Страница 392: ...11 24 745 Transformer Management Relay GE Power Management 11 1 COMMISSIONING SUMMARY 11 SETPOINT TABLES 11 ...
Страница 396: ...A 4 745 Transformer Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 398: ...B 2 745 Transformer Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 400: ...C 2 745 Transformer Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 406: ...vi 745 Transformer Management Relay GE Power Management ...
Страница 407: ...GE Power Management 745 Transformer Management Relay NOTES ...