H3-60
006-252-05
06.30.01 FM3040
FM-DP L
Service Manual
H3-60
MAINTENANCE 3. TROUBLESHOOTING
Error code
Error name
Significance
Probable cause and remedy
Detailed
information format
12E8
Sorter unit initialization
disabled error
Attempted to initialize the sorter, but the
sorter unit was found to be already
initialized unintentionally.
This occurs when the power of the sorter
unit was turned OFF/ON during M-Utility
operations.
Check the power state of the sorter unit.
Correct by following operation screen instructions.
2-3-F
12E9
Sorter motor speed
setting error
Attempted to set the sorter motor
speed, but it was not within the settable
range.
Check the sorter motor speed in the external file installed
(sif_unt.fil).
2-3-D
12EF
Sorter power off error
The sorter unit was unintentionally
initialized during idling or conveyance of
the sorter.
This occurs when the power of the sorter
unit was turned OFF/OF during normal
operations.
Correct by following operation screen instructions.
2-3-F
1311
Sorter disabled error
Attempted to execute the utility on the
sorter unit even though the sorter
disabled setting has been selected.(Not
used currently)
Replace the sorter unit.
None
1312
(*1)
Recording for temporary
use
User has selected the “TEMPORARY
USE” button.
No correction required.
None
1510
Polygon error
After turning ON the polygon, the
specified number of rotations is not
reached even after the specified time.
·Error of polygon alone
·Faulty cable connection
·Malfunction of the SCN board
1. Check the cable connection.
2. Check the polygon.
3. Replace the SCN board.
None
1511
One LD error
·LD error
·Faulty cable connection
·Malfunction of the SCN board
1. Check the cable connection.
2. Check the LD.
3. Replace the SCN board.
5-C
1513
Start-point detection
error
1. Check the cable connection.
2. Replace the start-point detection board.
3. Replace the SCN board.
None
The start-point detection signal is not
generated.
·Malfunction of the start-point detection
board.
·Malfunction of the optical unit (The
laser beam does not enter the start-
point detection sensor)
·Faulty cable connection
·Malfunction of the SCN board
*1: Main unit software version B01 or later.
Содержание FM-DP L
Страница 1: ...FM DP L Service Manual MAINTENANCE...
Страница 31: ...H1 29 006 252 02 10 22 99 FM2569 FM DP L Service Manual H1 29 MAINTENANCE 1 OUTLINE OF EQUIPMENT BLANK PAGE...
Страница 40: ...H3 7 2 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 7 2 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 41: ...H3 7 3 MAINTENANCE 3 TROUBLESHOOTING 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 7 3 BLANK PAGE...
Страница 42: ...H3 7 4 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 7 4 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 56: ...H3 19 2 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 19 2 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 57: ...H3 19 3 MAINTENANCE 3 TROUBLESHOOTING 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 19 3 BLANK PAGE...
Страница 58: ...H3 19 4 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 19 4 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 152: ...H3 89 16 006 252 05 06 30 01 FM3040 FM DP L Service Manual H3 89 16 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 244: ...H3 181 006 252 02 10 22 99 FM2569 FM DP L Service Manual H3 181 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 248: ...H3 185 006 252 02 10 22 99 FM2569 FM DP L Service Manual H3 185 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 252: ...H3 189 006 252 02 10 22 99 FM2569 FM DP L Service Manual H3 189 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 340: ...H3 277 006 252 02 10 22 99 FM2569 FM DP L Service Manual H3 277 MAINTENANCE 3 TROUBLESHOOTING BLANK PAGE...
Страница 349: ...FM DP L Service Manual PREVENTIVE MAINTENANCE...